Development and optimization of a quantitative analysis of main odorants causing off flavours in cork stoppers using
Patricia Jové1, Anna Pareras2, Raquel De Nadal3
1Catalan Cork Institute and Foundation, Institut Català del Suro (ICSuro), Girona, Spain.
Abstract:
A simple and sensitive method was developed and validated to simultaneously separate and determine the 2-Methoxy-3,5-dimethylpyrazine, 2-Isopropyl-3-methoxypyrazine, guaiacol, 2-Isobutyl-3-methoxypyrazine, 2-Methylisoborneol, geosmin, 2,4,6-Trichloroanisole, 2,3,4,6-Tetrachloroanisole, 2,4,6-Tribromoanisole and Pentachloroanisole in cork stoppers via headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography tandem mass spectrometry (GC-MS/MS). The influence of the fibre coating used, the extraction times and temperatures, the sodium chloride additions and the desorption temperatures were investigated. Once done, the optimial HS-SPME conditions established were divinylbenzene/carboxenpolydimethylsiloxane/polydimethylsiloxane (DVB/CAR/PDMS) fibres, a 50°C extraction temperature, 60-min extraction time, an ionic strength of 3-g sodium chlorid and a 290°C desorption temperature. The method showed a good linearity (R2 ≥ 0.994) within the tested range (from 0.1 to 50 ng L-1 ) for all the compounds. Using TCA-d10 and MIB-d3 as internal standards the precision, expressed as repeatability and reproducibility RSD, was <10% in both. Note that the limits of quantifications (LOQs) are below the sensory threshold levels for such compounds in water and wine. Good recoveries were obtained for cork macerates (from 100.4% to 126%) and when compared with other reported methods using HS-SPME in water and cork stopper samples, the present method had more analytes with the lowest limit of detection for most of the targeted compounds, along with good precision and recovery.
More Related Videos
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
04:36Author Spotlight: Exploring Tea Aroma Using Solvent-Assisted Flavor Evaporation Technique
Published on: May 26, 2023
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Qualitative Analysis
There are two main approaches to qualitative analysis:...
Development of Analytical Methods