Related Experiment Video
Updated: Nov 8, 2025

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Limitations and Pitfalls of Substrate Mapping for Ventricular Tachycardia
1Cardiac Electrophysiology Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio, USA.
Abstract:
The fundamental hypothesis of substrate mapping for scar-mediated ventricular tachycardia is that surrogates of the isthmus can be identified and targeted with ablation during sinus rhythm. These surrogates include electrocardiographic indications for electric discontinuity such as fractionation, split, late, and long potentials, also evident as sites displaying activation slowing. However, ablation strategies targeting these surrogates during sinus rhythm have resulted in unacceptably high rates of clinical failures, promoting the idea that a more widespread ablation may be required. High-resolution mapping technologies provide an opportunity to examine the substrate at greater detail; however, their use has not yet translated into improved clinical outcomes. This may be related to ongoing efforts to examine the same surrogates at higher resolution instead of using high-resolution technologies for discovering new and potentially more specific surrogates. This article reviews common limitations and pitfalls of substrate mapping and discusses new opportunities for high-resolution mapping to increase the accuracy of substrate mapping: 1) multielectrode mapping catheters provide an opportunity to rapidly examine the substrate during electrophysiological conditions that more closely simulate ventricular tachycardia by means of activation from different directions and coupling intervals; 2) electrogram annotation methods based on the maximal negative derivative of the extracellular potential or maximal voltage are often inaccurate in nonuniform anisotropic tissue. The use of multielectrode catheters may improve the accuracy of electrogram annotation by using spatiotemporal dispersion of single-beat acquisitions and a localized indifferent reference; and 3) resetting and entrainment remain important methods for studying re-entry for and guiding ablation.
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
09:36Dual-Dye Optical Mapping of Hearts from RyR2R2474S Knock-In Mice of Catecholaminergic Polymorphic Ventricular Tachycardia
Published on: December 22, 2023
Related Concept Videos
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Dysrhythmias III: Characteristics of Dysrhythmias
Dysrhythmias II: Classification of Tachyarrhythmias