Adaptive protection coordination scheme in microgrids using directional over-current relays with non-standard
Sergio D Saldarriaga-Zuluaga1,2, Jesús M López-Lezama2, Nicolás Muñoz-Galeano2
1Institución Universitaria Pascual Bravo, Facultad de Ingenieria, Departamento de Eléctrica, Calle 73 No. 73A - 226, Medellín 050036, Colombia.
Abstract:
Protection coordination of AC microgrids (MGs) is a challenging task since they can operate either in grid-connected or islanded mode which drastically modifies the fault currents. In this context, traditional approaches to protection coordination, that only consider the time multiplier setting (TMS) as a decision variable may no longer be able to guarantee network security. This paper presents a novel approach for protection coordination in AC MGs that incorporates non-standard characteristic features of directional over-current relays (OCRs). Three optimization variables are considered for each relay: TMS, maximum limit of the plug setting multiplier (PSM) and standard characteristic curve (SCC). The proposed model corresponds to a mixed integer non-linear programming problem. Four metaheuristic techniques were implemented for solving the optimal coordination problem, namely: particle swarm optimization (PSO), genetic algorithm (GA), teaching-learning based optimization (TLBO) algorithm and shuffled frog leaping algorithm (SFLA). Numerous tests were run on an IEC MG as well as with the distribution portion of the IEEE 30-bus test system. Both systems incorporate distributed generation (DG) and feature several modes of operation. A comparison was made with other MG protection coordination approaches proposed in the specialized literature. In all cases, the proposed approach found reduced coordination times, evidencing the applicability and efficacy of the proposed approach.
More Related Videos
04:35Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
Published on: July 5, 2024
10:52Design, Instrumentation and Usage Protocols for Distributed In Situ Thermal Hot Spots Monitoring in Electric Coils using FBG Sensor Multiplexing
Published on: March 8, 2020
Related Concept Videos
Directional Relays
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Overcurrent Relays
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
Reclosers and Fuses
A comprehensive protection scheme for radial distribution...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...