Comparison of pre- and post-contrast-enhanced attenuation correction using a CAIPI-accelerated T1-weighted Dixon
Nils Martin Bruckmann1, Maike E Lindemann2, Johannes Grueneisen3
1Department of Diagnostic and Interventional Radiology, University Dusseldorf, Medical Faculty, Dusseldorf, D-40225, Germany.
Objectives:
To investigate the influence of contrast agent administration on attenuation correction (AC) based on a CAIPIRINHA (CAIPI)-accelerated T1-weighted Dixon 3D-VIBE sequence in 68Ga-DOTATOC PET/MRI.
Material And Methods:
Fifty-one patients with neuroendocrine tumors underwent whole-body 68Ga-DOTATOC PET/MRI for tumor staging. Two PET reconstructions were performed using AC-maps that were created using a high-resolution CAIPI-accelerated Dixon-VIBE sequence with an additional bone atlas and truncation correction using the HUGE (B0 homogenization using gradient enhancement) method before and after application of Gadolinium (Gd)-based contrast agent. Standardized uptake values (SUVs) of 21 volumes of interest (VOIs) were compared between in both PET data sets per patient. A student's t-test for paired samples was performed to test for potential differences between both AC-maps and both reconstructed PET data sets. Bonferroni correction was performed to prevent α-error accumulation, p < 0.0024 was considered to indicate statistical significance.
Results:
Significant quantitative differences between SUVmax were found in the perirenal fat (19.65 ± 48.03 %, p < 0.0001), in the axillary fat (17.46 ± 63.67 %, p < 0.0001) and in the dorsal subcutaneous fat on level of lumbar vertebral body L4 (10.26 ± 25.29 %, p < 0.0001). Significant differences were also evident in the lungs apical (5.80 ± 10.53 %, p < 0.0001), dorsal at the level of the pulmonary trunk (15.04 ± 19.09 %, p < 0.0001) and dorsal in the basal lung (51.27 ± 147.61 %, p < 0.0001).
Conclusion:
The administration of (Gd)-contrast agents in this study has shown a considerable influence on the AC-maps in PET/MRI and, consequently impacted quantification in the reconstructed PET data. Therefore, dedicated PET/MRI staging protocols have to be adjusted so that AC-map acquisition is performed prior to contrast agent administration.
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies III: Computed Tomography
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI