Related Experiment Video
Updated: Nov 8, 2025

Database-guided Flow-cytometry for Evaluation of Bone Marrow Myeloid Cell Maturation
Published on: November 3, 2018
A benchmark bone marrow aspirate smear dataset and a multi-scale cell detection model for the diagnosis of
Jie Su1, Jinjun Han1, Jinming Song2
1School of Computer Science and Engineering, University of Jinan, Jinan, China; Shandong Provincial Key Laboratory of Network Based Intelligent Computing, University of Jinan, China.
Abstract:
Research on pathological diagnosis of hematopoietic disorders based on bone marrow aspirate smear images has attracted more and more attention with the development of deep learning methods. However, high quality bone marrow aspirate smear image datasets are not readily available because of the time, the efforts, and the medical knowledge required in the acquisition and manual annotation images. In order to facilitate the research of automated diagnosis of hematological disorders, we constructed a high quality Bone Marrow Aspirate Smear Image Dataset (BMASID), which contains 230 bone marrow aspirate smear images, all with the corresponding labeled images. We used additional clinical images as testing data, which are more challenging because of image noise, cell overlap, cell adhesion, blurred borders of cells and ambiguous types of cells. We also proposed a Cell Recognition Network (CRNet) that was trained on this benchmark dataset. CRNet is comprised of a cell detector to locate and recognize cells in the bone marrow aspirate images, and a cell classifier to classify the types of cells. New anchors and novel evaluation metrics are proposed and applied in CRNet. Benchmark evaluations of the proposed CRNet demonstrated the satisfactory performance of our state-of-the-art methods. Experimental results show that the detection precision by detector is more than 83%, and it is better when compared with other detection methods. After the cell type confirmation by the cell classifier, the precision is more than 95%. Compared with the most popular evaluation metrics Intersection over Union (IoU) and the newly proposed Generalized Intersection over Union (GIoU) used in the object detection benchmarks, our evaluation metrics are more suitable for the cell detection task with ambiguous cell boundaries. The proposed bone marrow aspirate smear image dataset and the proposed evaluation metrics can be used in the training and the evaluation of cell detection models, which contributes to future research in the pathological analysis and auxiliary diagnostic methods of hematological disorders. The codes are available at: https://github.com/SuJie-Med/hematolgical-disorders.
More Related Videos
09:31Automated Quantification of Hematopoietic Cell – Stromal Cell Interactions in Histological Images of Undecalcified Bone
Published on: April 8, 2015
09:07A Human Bone Marrow 3D Model to Investigate the Dynamics and Interactions Between Resident Cells in Physiological or Tumoral Contexts
Published on: December 16, 2022