Related Experiment Video
Updated: Nov 8, 2025

Effects of Surgical Masks on Cardiopulmonary Function in Healthy Subjects
Published on: February 12, 2021
Mitigation of Aerosols Generated During Exercise Testing With a Portable High-Efficiency Particulate Air Filter With
Andrés Garzona-Navas1, Pavol Sajgalik2, Ibolya Csécs1
1Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN.
Background:
The role of portable high-efficiency particulate air (HEPA) filters for supplemental aerosol mitigation during exercise testing is unknown and might be relevant during COVID-19 pandemic.
Research Question:
What is the effect of portable HEPA filtering on aerosol concentration during exercise testing and its efficiency in reducing room clearance time in a clinical exercise testing laboratory?
Study Design And Methods:
Subjects were six healthy volunteers aged 20 to 56 years. In the first experiment, exercise was performed in a small tent with controlled airflow with the use of a stationary cycle, portable HEPA filter with fume hood, and particle counter to document aerosol concentration. Subjects performed a four-stage maximal exercise test that lasted 12 min plus 5 min of pretest quiet breathing and 3 min of active recovery. First, they exercised without mitigation then with portable HEPA filter running. In a separate experiment, room aerosol clearance time was measured in a clinical exercise testing laboratory by filling it with artificially generated aerosols and measuring time to 99.9% aerosol clearance with heating, ventilation, and air conditioning (HVAC) only or HVAC plus portable HEPA filter running.
Results:
In the exercise experiment, particle concentrations reached 1,722 ± 1,484/L vs 96 ± 124/L (P < .04) for all particles (>0.3 μm), 1,339 ± 1,281/L vs 76 ± 104/L (P < .05) for smaller particles (0.3 to 1.0 μm), and 333 ± 209/L vs 17 ± 19/L (P < .01) for larger particles (1.0 to 5.0 μm) at the end of the protocol in a comparison of mitigation vs portable HEPA filter. Use of a portable HEPA filter in a clinical exercise laboratory clearance experiment reduced aerosol clearance time 47% vs HVAC alone.
Interpretation:
The portable HEPA filter reduced the concentration of aerosols generated during exercise testing by 96% ± 2% for all particle sizes and reduced aerosol room clearance time in clinical exercise testing laboratories. Portable HEPA filters therefore might be useful in clinical exercise testing laboratories to reduce the risk of COVID-19 transmission.
More Related Videos
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
09:29An Air-liquid Interface Bronchial Epithelial Model for Realistic, Repeated Inhalation Exposure to Airborne Particles for Toxicity Testing
Published on: May 13, 2020
Related Concept Videos
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...