Related Experiment Video
Updated: Nov 8, 2025

Scalable Isolation and Purification of Extracellular Vesicles from Escherichia coli and Other Bacteria
Published on: October 13, 2021
Facile syringe filter-enabled bacteria separation, enrichment, and buffer exchange for clinical isolation-free
Pengfei Zhang1, Aniruddha M Kaushik2, Kathleen E Mach3
1Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA. thwang@jhu.edu.
Abstract:
The development of accelerated methods for pathogen identification (ID) and antimicrobial susceptibility testing (AST) for infectious diseases is necessary to facilitate evidence-based antibiotic therapy and reduce clinical overreliance on broad-spectrum antibiotics. Towards this end, droplet-based microfluidics has unlocked remarkably rapid diagnostic assays with single-cell and single-molecule resolution. Yet, droplet platforms invariably rely on testing purified bacterial samples that have been clinically isolated after lengthy (>16 h) plating. While plating-based clinical isolation is important for enriching and separating out bacteria from background in clinical samples and also facilitating buffer exchange, it creates a diagnostic bottleneck that ultimately precludes droplet-based methods from achieving significantly accelerated times-to-result. To alleviate this bottleneck, we have developed facile syringe filter-enabled strategies for bacterial separation, enrichment, and buffer exchange from urine samples. By selecting appropriately sized filter membranes, we separated bacterial cells from background particulates in urine samples and achieved up to 91% bacterial recovery after such 1-step filtration. When interfaced with droplet-based detection of bacterial cells, 1-step filtration improved the limit of detection for bacterial ID and quantification by over an order of magnitude. We also developed a facile buffer exchange strategy to prepare bacteria in urine samples for droplet-based AST that achieved up to 10-fold bacterial enrichment during buffer exchange. Our filtration strategies, can be easily integrated into droplet workflows, enable clinical isolation-free sample-to-answer ID and AST, and significantly accelerate the turnaround of standard infectious disease diagnostic workflows.
More Related Videos
07:34Isolation of Single Intracellular Bacterial Communities Generated from a Murine Model of Urinary Tract Infection for Downstream Single-cell Analysis
Published on: April 16, 2019
06:28Author Spotlight: Asymmetric Field Flow Fractionation for Bioreactor Integration
Published on: February 2, 2024