Related Experiment Video
Updated: Nov 7, 2025

Construction of a Compact Low-Cost Radiation Shield for Air-Temperature Sensors in Ecological Field Studies
Published on: November 6, 2018
Improved methods for estimating mean radiant temperature in hot and sunny outdoor settings
Jennifer K Vanos1, Konrad Rykaczewski2, Ariane Middel3
1School of Sustainability, Arizona State University, Tempe, AZ, USA. jvanos@asu.edu.
Abstract:
Thermal comfort research has utilized various sensors and models to estimate the mean radiant temperature (MRT) experienced by a human, including the standard black globe thermometer (SGT), acrylic globe thermometers (AGT), and cylindrical radiation thermometers (CRT). Rather than directly measuring radiation, a temperature is measured in the center of these low-cost sensors that can be related to MRT after theoretically accounting for convection. However, these sensors have not been systematically tested under long-term hot and clear conditions. Further, under variable weather conditions, many issues can arise due to slow response times, shape, inaccuracies in material properties and assumptions, and color (albedo, emissivity) inconsistencies. Here, we assess the performance of MRT produced by various heat transfer models, with and without new average surface temperature ([Formula: see text]) correction factors, using five instruments-the SGT (15 cm, black), tan and black CRTs, gray and black 38 mm AGTs-compared to 3D integral radiation measurements. Measurements were taken on an unobscured roof throughout summer-to-early-fall months in Tempe, Arizona, examining 58 full-sun days. Deviations without correcting for asymmetrical surface heating-found to be the main cause of errors-reached ± 15-20 °C MRT. By accounting for asymmetric heating through [Formula: see text] calculations, new corrective algorithms were derived for the low-cost sensor models. Results show significant improvements in the estimated MRT error for each sensor (i.e., ∆MRTmodel - IRM) when applying the [Formula: see text] corrections. The tan MRTCRT improved from 1.9 ± 6.2 to -0.1 ± 4.4 °C, while the gray AGT and SGT showed improvements from -1.6 ± 7.2 to -0.4 ± 6.3 °C and - 6.6 ± 6.4 to - 0.03 ± 5.7 °C, respectively. The new corrections also eliminated dependence on other meteorological factors (zenith, wind speed). From these results, we provide three simple equations for CRT, AGT, and SGT correction for future research use under warm-hot and clear conditions. This study is the most comprehensive empirical assessment of various low-cost instruments with broad applicability in urban climate and biometeorological research.
More Related Videos
09:00Indoor Experimental Assessment of the Efficiency and Irradiance Spot of the Achromatic Doublet on Glass ADG Fresnel Lens for Concentrating Photovoltaics
Published on: October 27, 2017
06:27Measurement of Aerosols Optical Thickness of the Atmosphere using the GLOBE Handheld Sun Photometer
Published on: May 29, 2019
Related Concept Videos
Hot Weather Concreting
Mitigating the heat increase in concrete can be economically achieved by shading aggregate stockpiles to prevent heating from solar radiation,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Radiation: Applications
The average...
Absorption of Radiation
Design Example: Managing Concrete Workability
Factors Affecting Body Temperature
Factors may include: