Related Experiment Video
Updated: Nov 7, 2025

Electroantennography-based Bio-hybrid Odor-detecting Drone using Silkmoth Antennae for Odor Source Localization
Published on: August 27, 2021
Circularly Polarized Dual-Band LoRa/GPS Antenna for a UAV-Assisted Hazardous Gas and Aerosol Sensor
Fermín Mira1, Xavier Artiga1, Ignacio Llamas-Garro1
1Centre Tecnològic de Telecomunicacions de Catalunya (CTTC/CERCA), Av. Carl Friedrich Gauss 7, Castelldefels, 08860 Barcelona, Spain.
Abstract:
UAV assisted wireless sensor networks play a key role in the detection of toxic gases and aerosols. UAVs can be used to remotely deploy sensor nodes and then collect gas concentration readings and GPS positioning from them to delimit an affected area. For such purpose, a dual-band communication system is required, supporting GPS reception, and sensor reading data transfer, which is chosen to be at 2.4 GHz using LoRa physical layer. In this work we propose a switched-beam antenna subsystem for the sensor nodes capable not only of satisfying the dual band requirements but also of maximizing communication range or energy consumption through a good antenna polarization match and improved antenna gain. This antenna subsystem is built using dual-port, dual-band, circularly polarized antenna elements, whose design and experimental validation is carefully detailed. A low profile microstrip stacked structure has been used to obtain return loss in both bands better than 15 dB, axial ratios below 1.5 dB, and wide -3 dB beamwidths around 90° and 75° for GPS and 2.4 GHz bands, respectively, thus limiting the gain reduction of the switched-beam system in critical sensor orientations. Special attention has been paid to reduce the coupling between both ports through the optimization of the relative placement of both patches and their feeding points. The measured coupling is below -30 dB.
Related Concept Videos
Field Application of Global Positioning System
Types of Global Positioning System Surveys
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Errors in Global Positioning System

