Reduction of Load Capacity of Fiber Cement Board Facade Cladding under the Influence of Fire
Krzysztof Schabowicz1, Paweł Sulik2, Łukasz Zawiślak1
1Faculty of Civil Engineering, Wrocław University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370 Wrocław, Poland.
Abstract:
The paper analyzes the issue of the reduction of load capacity in fiber cement board during a fire. Fiber cement boards were put under the influence of fire by using a large-scale facade model. Such a model is a reliable source of knowledge about the behavior of facade cladding and the way fire spreads. One technical solution for external walls-a ventilated facade-is gaining popularity and is used more and more often. However, the problem of the destruction during a fire of a range of different materials used in external facade cladding is insufficiently recognized. For this study, the authors used fiber cement boards as the facade cladding. Fiber cement boards are fiber-reinforced composite materials, mainly used for facade cladding, but also used as roof cladding, drywall, drywall ceiling and floorboards. This paper analyzes the effect of fire temperatures on facade cladding using a large-scale facade model. Samples were taken from external facade cladding materials that were mounted on the model at specific locations above the combustion chamber. Subsequently, three-point bending flexural tests were performed and the effects of temperature and the integrals of temperature and time functions on the samples were evaluated. The three-point bending flexural test was chosen because it is a universal method for assessing fiber cement boards, cited in Standard EN 12467. It also allows easy reference to results in other literature.
Related Concept Videos
Fiber Reinforced Concrete
Composite Masonry Walls
Masonry Curtain Walls
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Masonry Loadbearing Walls
Fatigue Strength of Concrete