Related Experiment Video
Updated: Nov 7, 2025

Application of Ultrasound and Shear Wave Elastography Imaging in a Rat Model of NAFLD/NASH
Published on: April 20, 2021
Assessing Baveno VI Criteria Using Liver Stiffness Measured with a 2D-Shear Wave Elastography Technique
Renata Fofiu1, Felix Bende1, Alina Popescu1
1Department of Gastroenterology and Hepatology, "Victor Babeș" University of Medicine and Pharmacy, 300041 Timișoara, Romania.
Abstract:
The present study evaluates the performance of Baveno VI criteria, using liver stiffness (LS) assessed with a 2D-SWE elastography technique, for predicting high-risk varices (HRV) in patients with compensated advanced chronic liver disease (cACLD). A secondary aim was to determine whether the use of spleen stiffness measurements (SSMs), as additional criteria, increases the performance of the 2D-SWE Baveno VI criteria. Data were collected from 208 subjects with cACLD, who underwent abdominal ultrasound, liver and spleen stiffness measurements, and upper digestive endoscopy. HRV were defined as grade 1 esophageal varices (EV) with red wale marks, grade 2/3 EV, and gastric varices. A total of 35.6% (74/208) of the included subjects had HRV. The optimal LS cut-off value for predicting HRV was 12 kPa (AUROC-0.80). Using both LS cut-off value < 12 kPa and a platelet cut-off value > 150 × 109 cells/L as criteria to exclude HRV, 52/208 (25%) subjects were selected, 88.5% (46/52) were without EV, 9.6% (5/52) had grade 1 EV, and 1.9% (1/52) had HRV. Thus 98% of the subjects were correctly classified as having or not having HRV and 25% of the surveillance endoscopies could have been avoided. Using SS < 13.2 kPa and a platelet cut-off value > 150 × 109 cells/L as additional criteria for the patients that were outside the initial ones, 32.7% of the surveillance endoscopies could have been avoided.
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...