Evaluation of Fluid Overload by Bioelectrical Impedance Vectorial Analysis
Published on: August 17, 2022
Comparison of Bioelectrical Impedance-Based Methods on Body Composition in Young Patients with Obesity
Alexandra Thajer1, Gabriele Skacel1, Katharina Truschner1
1Division of Pediatric Pulmonology, Allergology and Endocrinology, Department of Pediatrics and Adolescent Medicine, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria.
Abstract:
(1) Background: The determination of body composition is an important method to investigate patients with obesity and to evaluate the efficacy of individualized medical interventions. Bioelectrical impedance-based methods are non-invasive and widely applied but need to be validated for their use in young patients with obesity. (2) Methods: We compiled data from three independent studies on children and adolescents with obesity, measuring body composition with two bioelectrical impedance-based devices (TANITA and BIACORPUS). For a small patient group, additional data were collected with air displacement plethysmography (BOD POD) and dual-energy X-ray absorptiometry (DXA). (3) Results: Our combined data on 123 patients (age: 6-18 years, body mass index (BMI): 21-59 kg/m²) and the individual studies showed that TANITA and BIACORPUS yield significantly different results on body composition, TANITA overestimating body fat percentage and fat mass relative to BIACORPUS and underestimating fat-free mass (p < 0.001 for all three parameters). A Bland-Altman plot indicated little agreement between methods, which produce clinically relevant differences for all three parameters. We detected gender-specific differences with both methods, with body fat percentage being lower (p < 0.01) and fat-free mass higher (p < 0.001) in males than females. (4) Conclusions: Both bioelectrical impedance-based methods provide significantly different results on body composition in young patients with obesity and thus cannot be used interchangeably, requiring adherence to a specific device for repetitive measurements to ascertain comparability of data.
More Related Videos
04:05Author Spotlight: Unveiling Prognostic Indicators in Heart Failure - The Role of Phase Angle and Bioelectrical Impedance Analysis
Published on: June 30, 2023
07:44Author Spotlight: Implementation of BIVA for Analyzing Disease Risk Factors in Patients with Low Body Cell Mass
Published on: July 14, 2023
Related Concept Videos
Drug Dosing: Obese Patients
Pharmacokinetics in Obese Patients: Drug Absorption and Distribution
Obesity