Related Experiment Video
Updated: Nov 7, 2025

11:53
The Modular Design and Production of an Intelligent Robot Based on a Closed-Loop Control Strategy
Published on: October 14, 2017
11.9K
A Security Scheme Based on Intranal-Adding Links for Integrated Industrial Cyber-Physical Systems.
Dandan Zhao1, Can Liu1, Hao Peng1
1College of Mathematics and Computer Science, Zhejiang Normal University, Jinhua 321004, China.
Sensors (Basel, Switzerland)
|April 30, 2021
Summary
This study introduces a security scheme for industrial Cyber-Physical Systems (CPS) to prevent cascading failures. A new intranal-adding links strategy was found to enhance system security and optimize network topology.
Area of Science:
- Cyber-Physical Systems
- Network Security
- Industrial Internet
Background:
- Industrial Cyber-Physical Systems (CPS) are complex, interdependent networks facing cascading failure risks.
- The integration of industrial CPS is growing in the Internet of Everything era.
Purpose of the Study:
- To propose a security scheme for integrated industrial CPS environments.
- To analyze and mitigate the risk of cascading failures in industrial CPS.
Main Methods:
- Calculating the largest connected component to assess security under random attacks.
- Comparing cascading failure risks across different intranal-adding link strategies.
- Simulating and verifying the effectiveness of proposed security strategies.
Main Results:
- The proposed intranal-adding links security scheme effectively enhances industrial CPS security.
- A specific exchange strategy demonstrated superior performance in mitigating cascading failures.
- Simulation results validated the effectiveness of the security strategy.
Conclusions:
- The developed security scheme and link strategies can optimize industrial CPS topology.
- This research provides insights for designing more resilient and secure industrial CPS.
- The findings are crucial for managing risks in increasingly integrated industrial systems.
Related Concept Videos
Pilot and Numeric Relaying
193
Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying:
193
Integrated Healthcare System
2.0K
An integrated healthcare system (IHS) is a set of organizations that provides for or arranges to provide coordinated and continuous service to a defined population. The IHS takes responsibility for that particular population's health status and outcome, both clinically and fiscally. An integrated healthcare system is a well-organized, well-coordinated, and collaborative network. The integrated delivery system is a network that connects different healthcare providers to deliver organized,...
2.0K
Nursing Clinical Information System
984
Nursing Clinical Information System (NCIS)
A Nursing Clinical Information System (NCIS) is a specialized type of healthcare information system tailored to meet the unique needs of nursing practice. It incorporates the principles of nursing informatics to streamline information management and improve the quality of care delivery.
Critical attributes of NCIS include:
A Nursing Clinical Information System (NCIS) is a specialized type of healthcare information system tailored to meet the unique needs of nursing practice. It incorporates the principles of nursing informatics to streamline information management and improve the quality of care delivery.
Critical attributes of NCIS include:
984
Electro-mechanical Systems
1.3K
Electromechanical systems are intricate configurations that effectively combine electrical and mechanical elements to achieve a desired outcome. Central to many of these systems is the DC motor, a device that converts electrical energy into mechanical motion, enabling various applications ranging from simple fans to complex robotic mechanisms.
A key component of the DC motor is the armature, a rotating circuit positioned within a magnetic field. As an electric current passes through the...
A key component of the DC motor is the armature, a rotating circuit positioned within a magnetic field. As an electric current passes through the...
1.3K
Zones of Protection
464
In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
464
IP3/DAG Signaling Pathway
13.2K
Membrane lipids such as phosphatidylinositol (PI) are precursors for several membrane-bound and soluble second messengers. Specific kinases phosphorylate PI and produce phosphorylated inositol phospholipids. One such inositol phospholipids are the phosphatidylinositol-4,5 bisphosphate [PI(4,5)P2], present in the inner half of the lipid bilayer. Upon ligand binding, GPCR stimulates Gq proteins to turn on phospholipase Cꞵ. Activated phospholipase Cꞵ cleaves PI(4,5)P2 and...
13.2K

