Related Experiment Video
Updated: Nov 7, 2025

Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Inelastic Responses and Finite Element Predictions of Fiber Cementitious Composite and Concrete Columns
1Department of Architectural Engineering, Chosun University, Gwangju 61452, Korea.
Abstract:
In this research, reinforced concrete (RC) and strain-hardening cementitious composite (SHCC) columns subjected to lateral loads combined with a constant load were investigated, both by experiments and predictions, with two distributed inelastic finite element models established by the stiffness and flexibility formulations. SHCC applied in the column plastic hinge region could not only enhance the lateral load and displacement capacities of columns but also offer effective advantages in the control of bending and shear cracks induced by multiple microcracks, the prevention of the spalling of cover concrete, and the resistance to buckling of steel bars. With the layered cross-sectional approach using constitutive laws of SHCC considering a proposed model of the post-cracked high-ductile tensile characteristics, as well as concrete and reinforcing steel bars, an inelastic beam-column finite element model was presented with a distributed flexibility formulation. In comparison with experiments concerning the RC and reinforced strain-hardening cementitious composite (R-SHCC) columns, the current flexibility method showed relatively accurate estimations in the lateral load and displacement responses of column systems as well as in localized nonlinear responses of cross-section as estimated in axial strains of longitudinal reinforcing steel bars. In comparison with the stiffness method, the current flexibility method gave more accurate solutions at both element and structural levels, as manifested in the experiments and analysis solutions.
More Related Videos
05:26Determination of the Mechanical Properties of Flexible Connectors for Use in Insulated Concrete Wall Panels
Published on: October 19, 2022
11:28A Coupled Experiment-finite Element Modeling Methodology for Assessing High Strain Rate Mechanical Response of Soft Biomaterials
Published on: May 18, 2015
Related Concept Videos
Design of Columns under a Centric Load
Euler's formula is applicable under the assumption that the column is a perfect, straight, homogenous prism, and it is operating...
Fiber Reinforced Concrete
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Members Made of Elastoplastic Material
As the bending moment...
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...