Air Filter Devices Including Nonwoven Meshes of Electrospun Recombinant Spider Silk Proteins
Published on: May 8, 2013
Preliminary Evaluation of Filtration Efficiency and Differential Pressure ASTM F3502 Testing Methods of Non-Medical
Charles Freeman1, Reuben Burch2, Lesley Strawderman2
1School of Human Sciences, Mississippi State University, Starkville, MS 39762, USA.
Abstract:
Research surrounding the mandated use of non-medical fabric masks is inconsistent and often confusing when compared to the standard N95. A recently published standard from ASTM International and the Centers for Disease Control and Prevention attempts to normalize evaluation procedures. The purpose of this study is to conduct a preliminary evaluation of the new methods for testing filtration efficiency of masks outlined by ASTM International F3502, where results can be directly compared to standards outlined for non-medical fabric masks. Eleven consumer non-medical fabric masks were tested for filtration efficiency and airflow resistance using a face filtration mount in accordance with the newly released ASTM International standard for facial barriers. The mean FE% (SD) ranged from 0.46% (0.44) to 11.80% (2.76) with the 3-layer athletic mesh having the highest performance and the highest deviations. All the masks tested following the procedure failed to meet to minimum FE of 20%; however all masks performed below the minimum upper limits for airflow resistance. Using a non-medical fabric masks as the sole mitigation strategy may not be as effective, as previously reported. With efforts to standardize and regulate the non-medical fabric mask market, this study demonstrates a variety of currently available consumer mask products do not meet the minimum standards nor are these remotely close to the standards of surgical or N95 masks.
Related Concept Videos
Filtration
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration