Diagnostic Performance of Conventional X-ray for Detecting Foreign Bodies in the Upper Digestive Tract: A Systematic
Ta-Wei Yang1,2, Yi-Chung Yu3,4, Yen-Yue Lin1,2
1Department of Emergency Medicine, Taoyuan Armed Forces General Hospital, Taoyuan 325, Taiwan.
Abstract:
Foreign body (FB) ingestion is a common clinical problem in acute settings. Detecting FBs in the upper digestive tract is challenging. The conventional X-ray is usually the first-line imaging tool to detect FBs. However, its diagnostic performance is inconsistent in the literature. In this study, we performed a systematic review and meta-analysis to determine the diagnostic performance of the conventional X-ray for detecting FBs in the upper digestive tract. We conducted a systematic search of PubMed, Embase, Cochrane Library, Web of Science, and Scopus until 1 August 2020. Prospective or retrospective studies investigating the diagnostic accuracy of conventional X-rays for detecting FBs in the upper digestive tract in patients of all ages were included. The Quality Assessment of Studies of Diagnostic Accuracy-2 tool was used to review the quality of included studies. We used a bivariate random-effects model to calculate diagnostic accuracy parameters. Heterogeneity was assessed using I2 statistics. We included 17 studies (n = 4809) in the meta-analysis. Of the 17 studies, most studies were rated as having a high risk of bias. Conventional X-rays had a pooled sensitivity of 0.58 (95% confidence interval [CI] = 0.36-0.77, I2 = 98.52) and a pooled specificity of 0.94 (95% CI = 0.87-0.98, I2 = 94.49) for detecting FBs in the upper digestive tract. The heterogeneity was considerable. The area under the summary receiver operating characteristic curve was 0.91 (95% CI = 0.88-0.93). Deek's funnel plot asymmetry test results revealed no significant publication bias (p = 0.41). The overall sensitivity and specificity of conventional X-rays were low and high, respectively, for detecting FBs in the upper digestive tract. Hence, conventional X-rays to exclude patients without upper FBs in the digestive tract are not recommended. Further imaging or endoscopic examinations should be performed for at-risk patients.
Related Concept Videos
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Peptic Ulcer Disease III: Clinical Manifestations and Diagnostic Studies
Few clinical manifestations differentiate gastric ulcers from duodenal ulcers. Distinctions in the location, timing, and pain relief are crucial for healthcare providers in differentiating between gastric and duodenal ulcers during clinical assessments.
X-ray Imaging
Radiological Investigation I: X-ray and CT
Serum Laboratory Studies, Stool Test, Breath Test