Related Experiment Video
Updated: Nov 7, 2025

Measurement of Ultrafast Vibrational Coherences in Polyatomic Radical Cations with Strong-Field Adiabatic Ionization
Published on: August 6, 2018
Fundamental Frequency and Jitter Percent in MDVP and PRAAT
Ahmed A Mohammed1, Ahmed Nagy2
1Department of ENT, Ain Shams University; Assistant professor of Phoniatrics, Cairo, Egypt.
Purpose:
This study initially investigated the relationship between Fundamental Frequency and Jitter Percent across and within MDVP and PRAAT. Subsequently, it explored if the measured acoustic signal's Length or the analysis temporal segment selection impacts potential correlation across the tools' measures.
Methods:
We collected forty-two Maximum Phonation Time acoustic signals from 10 participants with Healthy Voices in a standardized setting. We excluded from enrollment any potential participants having a history of voice disorders or showing an abnormality in a pre-study assessment.
Results:
There is no correlation between Jitter percent's values and Fundamental Frequency within either Tool in our healthy voice samples. The Length of the acoustic signal and temporal analysis selection impact the correlation between Jitter Percent measurements across the two tools; The correlation between Fundamental Frequency measurements across the devices was not affected. Means of Fundamental Frequency did not differ across the two devices but show a persistent pattern of greater values in MDVP. Jitter Percent measurements were significantly higher in MDVP CONCLUSIONS: There is a potential for clinicians using PRAAT assessments in the clinic to make inferences from research using MDVP as an analysis tool. Further work is needed in patients with Voice disorders to explore that possibility.
Related Concept Videos
Frequency-Domain Interpretation of PD Control
The proportional control gain, combined with the...
Determination of Expected Frequency
Effective Value of a Periodic Waveform
The effective value of a periodic current represents the direct current (DC) that conveys the same average power to a resistor as the periodic current itself. This concept is crucial when assessing AC circuits. To determine the...
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...

