Background:
Initial fluid resuscitation is presumed to be important for treating shock in the resuscitation phase. However, little is known how quickly and easily a physician could perform a rapid infusion with a syringe.
Objectives:
We hypothesised that using a high-flow three-way stopcock (HTS) makes initial fluid resuscitation faster and easier than using a normal-flow three-way stopcock (NTS).
Methods:
This was a simulation study with a prospective, nonblinded randomised crossover design. Twenty physicians were randomly assigned into two groups. Each participant used six peripheral intravenous infusion circuits, three with the HTS and the others with the NTS, and three cannulae, 22, 20, and 18 gauge (G). The first group started with the HTS first, while the other started with the NTS first. They were asked to inject the fluid as quick as possible. We compared the time until the participants finished rapid infusions of 500 ml of 0.9% saline and the practitioner's effort.
Results:
In infusion circuits attached with the 22G cannula, the mean difference using the HTS and the NTS (95% confidence interval [CI]) was 16.30 ml/min (7.65-24.94) (p < 0.01). In those attached with the 20G cannula, the mean difference (95% CI) was 23.47 (12.43-34.51) (p < 0.01). In those attached with the 18G cannula, the mean difference (95% CI) was 42.53 (28.68-56.38) (p < 0.01).
Conclusions:
This study revealed that the push-and-pull technique using the HTS was faster, easier, and less tiresome than using the NTS, with a statistically significant difference. In the resuscitation phase, initial and faster infusion is important. If only a single physician or other staff member such as a nurse is attending or does not have accessibility to any other devices in such an environment where medical resources are scarce, performing the push-and-pull technique using the HTS could help a physician to perform fluid resuscitation faster. By setting up the HTS instead of the NTS from the beginning, we would be able to begin fluid resuscitation immediately while preparing other devices.
More Related Videos
Related Concept Videos
Crossover Experiments
Crossover designs are performed even with smaller sample sizes since the samples can act as their controls. These are better than simple randomized trials since patients are exposed to all the treatments.
Bioequivalence Experimental Study Designs: Repeated Measures, Cross-Over, Carry-Over, and Latin Square Designs
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
Design Example: Flow Through a Fire Extinguisher
The key to understanding how the...