Related Experiment Video
Updated: Nov 7, 2025

Author Spotlight: Advancing Cellular and Protein Engineering to Control Biological Functions and Develop Novel Therapies
Published on: September 27, 2024
Diagnostic Accuracy with Total Adenosine Deaminase as a Biomarker for Discriminating Pleural Transudates and Exudates
Bernardo Henrique Ferraz Maranhão1, Cyro Teixeira da Silva Junior2, Jorge Luiz Barillo3
1Department of Specialized Medicine, Federal University of the State of Rio de Janeiro, Brazil.
Background:
An initial step in the evaluation of patients with pleural effusion syndrome (PES) is to determine whether the pleural fluid is a transudate or an exudate.
Objectives:
To investigate total adenosine deaminase (ADA) as a biomarker to classify pleural transudates and exudates.
Methods:
An assay of total ADA in pleural fluids (P-ADA) was observed using a commercial kit in a population-based cohort study.
Results:
157 pleural fluid samples were collected from untreated individuals with PES due to several causes. The cause most prevalent in transudate samples (21%, n = 33/157) was congestive heart failure (79%, 26/33) and that among exudate samples (71%, n = 124/157) was tuberculosis (28.0%, 44/124). There was no significant difference in the proportion of either sex between the transudate and exudate groups. The median values of P-ADA were significantly different (P < 0.0001) between both total exudates (18.4 U/L; IQR, 9.85-41.4) and exudates without pleural tuberculosis (11.0 U/L; IQR, 7.25-19.75) and transudates (6.85; IQR, 2.67-11.26). For exudates, the AUC was 0.820 (95% CI, 0.751-0.877; P < 0.001), with excellent discrimination. The optimum cut-off point in the ROC curve was determined as the level that provided the maximum positive likelihood ratio (PLR; 14.64; 95% CI, 2.11-101.9) and was22.0 U/L. For transudates, the AUC was 0.8245 (95% CI, 0.7470-0.9020; P < 0.0001). Internal validation of the AUC after 1000 resamples was evaluated with a tolerance minor than 2%. The clinical utility was equal to 92% (95% CI, 0.84 to 0.96, P < 0.05).
Conclusions:
P-ADA is a useful biomarker for distinguishing pleural exudates from transudates.
More Related Videos
11:29HPLC-based Assay to Monitor Extracellular Nucleotide/Nucleoside Metabolism in Human Chronic Lymphocytic Leukemia Cells
Published on: July 20, 2016
11:03Use of Capillary Electrophoresis Immunoassay to Search for Potential Biomarkers of Amyotrophic Lateral Sclerosis in Human Platelets
Published on: February 10, 2020