Pressure measurement characteristics of a micro-transducer and balloon catheters
William MacAskill1,2, Ben Hoffman1,2,3, Michael A Johnson4
1Respiratory and Exercise Physiology Research Group, School of Health and Wellbeing, University of Southern Queensland, Ipswich, Australia.
Abstract:
Respiratory pressure responses to cervical magnetic stimulation are important measurements in monitoring the mechanical function of the respiratory muscles. Pressures can be measured using balloon catheters or a catheter containing integrated micro-transducers. However, no research has provided a comprehensive analysis of their pressure measurement characteristics. Accordingly, the aim of this study was to provide a comparative analysis of these characteristics in two separate experiments: (1) in vitro with a reference pressure transducer following a controlled pressurization; and (2) in vivo following cervical magnetic stimulations. In vitro the micro-transducer catheter recorded pressure amplitudes and areas which were in closer agreement to the reference pressure transducer than the balloon catheter. In vivo there was a main effect for stimulation power and catheter for esophageal (Pes ), gastric (Pga ), and transdiaphragmatic (Pdi ) pressure amplitudes (p < 0.001) with the micro-transducer catheter recording larger pressure amplitudes. There was a main effect of stimulation power (p < 0.001) and no main effect of catheter for esophageal (p = 0.481), gastric (p = 0.923), and transdiaphragmatic (p = 0.964) pressure areas. At 100% stimulator power agreement between catheters for Pdi amplitude (bias =6.9 cmH2 O and LOA -0.61 to 14.27 cmH2 O) and pressure areas (bias = -0.05 cmH2 O·s and LOA -1.22 to 1.11 cmH2 O·s) were assessed. At 100% stimulator power, and compared to the balloon catheters, the micro-transducer catheter displayed a shorter 10-90% rise time, contraction time, latency, and half-relaxation time, alongside greater maximal rates of change in pressure for esophageal, gastric, and transdiaphragmatic pressure amplitudes (p < 0.05). These results suggest that caution is warranted if comparing pressure amplitude results utilizing different catheter systems, or if micro-transducers are used in clinical settings while applying balloon catheter-derived normative values. However, pressure areas could be used as an alternative point of comparison between catheter systems.
More Related Videos
Related Concept Videos
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Pipe Flowrate Measurement
The orifice meter is a simple,...
Pressure Gauges