Related Experiment Video
Updated: Nov 7, 2025

E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
Novel 1-L polyethylene glycol + ascorbate versus high-volume polyethylene glycol regimen for colonoscopy cleansing: a
Alessandro Repici1, Cristiano Spada2, Renato Cannizzaro3
1Endoscopy Unit, Humanitas Clinical and Research Center, IRCCS, Milan, Italy; Department of Biomedical Sciences, Humanitas University, Milan, Italy.
Background And Aims:
Adequate bowel cleansing is critical to ensure quality and safety of a colonoscopy. A novel 1-L polyethylene glycol plus ascorbate (1L-PEG+ASC) regimen was previously validated against low-volume regimens but was never compared with high-volume regimens.
Methods:
In a phase IV study, patients undergoing colonoscopy were randomized 1:1 to receive split-dose 1L PEG+ASC or a split-dose 4-L PEG-based regimen (4L-PEG) in 5 Italian centers. Preparation was assessed with the Boston Bowel Preparation Scale (BBPS) by local endoscopists and centralized reading, both blinded to the randomization arm. The primary endpoint was noninferiority of 1L-PEG+ASC in colon cleansing. Secondary endpoints were superiority of 1L-PEG+ASC, patient compliance, segmental colon cleansing, adenoma detection rate, tolerability, and safety.
Results:
Three hundred eighty-eight patients (median age, 59.8 years) were randomized between January 2019 and October 2019: 195 to 1L-PEG+ASC and 193 to 4L-PEG. Noninferiority of 1L-PEG+ASC was demonstrated for cleansing in both the entire colon (BBPS ≥ 6: 97.9% vs 93%; relative risk [RR], 1.03; 95% confidence interval [CI], 1.001-1.04; P superiority = .027) and in the right-sided colon segment (98.4% vs 96.0%; RR, 1.02; 95% CI, .99-1.02; P noninferiority = .013). Compliance was higher with 1L-PEG+ASC than with 4L-PEG (178/192 [92.7%] vs 154/190 patients [81.1%]; RR, 1.10; 95% CI, 1.05-1.12), whereas no difference was found regarding safety (moderate/severe side effects: 20.8% vs 25.8%; P = .253). No difference in adenoma detection rate (38.8% vs 43.0%) was found.
Conclusions:
One-liter PEG+ASC showed noninferiority compared with 4L-PEG in achieving adequate colon cleansing and provided a higher patient compliance. No differences in tolerability and safety were detected. (Clinical trial registration number: NCT03742232.).
More Related Videos
03:43Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
04:53A Clinical Trial Assessing the Safety, Efficacy, and Delivery of Olive-Oil-Based Three-Chamber Bags for Parenteral Nutrition
Published on: September 20, 2019
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures II: Colonoscopy
Drugs for Treatment of Constipation-Predominant IBS
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures III: Video Capsule Endoscopy