Related Experiment Video
Updated: Nov 6, 2025

Automated 3D Optical Coherence Tomography to Elucidate Biofilm Morphogenesis Over Large Spatial Scales
Published on: August 21, 2019
Biofouling control: the impact of biofilm dispersal and membrane flushing
Hendrik J de Vries1, Eva Kleibusch2, Gerben D A Hermes3
1Laboratory of Microbiology, Wageningen University & Research, Stippeneng 4, 6708 WE Wageningen, The Netherlands; Wetsus, European Centre of Excellence for Sustainable Water Technology, Oostergoweg 9, 8911 MA Leeuwarden, The Netherlands.
Abstract:
Pure culture studies have shown that biofilm dispersal can be triggered if the nutrient supply is discontinued by stopping the flow. Stimulating biofilm dispersal in this manner would provide a sustainable manner to control unwanted biofilm growth in industrial settings, for instance on synthetic membranes used to purify water. The response of multispecies biofilms to nutrient limitation has not been thoroughly studied. To assess biomass dispersal during nutrient limitation it is common practise to flush the biofilm after a stop-period. Hence, flow-stop-induced biomass removal could occur as a response to nutrient limitation followed by mechanical removal due to biofilm flushing (e.g. biofilm detachment). Here, we investigated the feasibility to reduce membrane biofouling by stopping the flow and flushing the membrane. Using a membrane fouling simulator, biomass removal from synthetic membranes after different stop-periods was determined, as well as biomass removal at different cross flow velocities. Biomass removal from membrane surfaces depended on the nutrient limiting period and on the flow velocity during the biofilm flush. When flushed at a low flow velocity (0.1 m.s-1), the duration of the stop-period had a large effect on the biomass removal rate, but when the flow velocity was increased to 0.2 m.s-1, the length of the stop period became less considerable. The flow velocity during membrane flushing has an effect on the bacterial community that colonized the membranes afterwards. Repetition of the stop-period and biofilm flushing after three repetitive biofouling cycles led to a stable bacterial community. The increase in bacterial community stability coincided with a decrease in cleaning effectivity to restore membrane performance. This shows that membrane cleaning comes at the costs of a more stable bacterial community that is increasingly difficult to remove.
Related Concept Videos
Biofilms
Biological Methods for Microbial Control
Physical Methods for Controlling Microbial Growth: Radiation and Filtration