Related Experiment Video
Updated: Nov 6, 2025

Enucleation of the Prostate for the Treatment of Benign Prostatic Hyperplasia Using a 980 nm Diode Laser
Published on: May 5, 2020
Endoscopic enucleation of the prostate (EEP). The same but different-a systematic review
M Pallauf1, T Kunit2, C Ramesmayer2
1Department of Urology, University Hospital Salzburg, Paracelsus Medical University, Salzburg, Austria. maximilian.pallauf@gmail.com.
Purpose:
Various techniques for EEP exist. They differ by surgical steps and the source of energy. It is assumed that the latter is of minor importance, whereas adherence to the anatomical enucleation template determines the postoperative result. So far, no systematic review highlights the differences between the energy sources in use for anatomical EEP. This study will address selfsame topic.
Methods:
A systematic review of the literature was completed on September 1st, 2020. Studies comparing HoLEP, ThuLEP, DiLEP, or BipolEP with TUR-P providing 12 months of postoperative follow-up were included. Two frequentist network meta-analyses were created to compare the techniques of EEP indirectly.
Results:
31 studies, including 4466 patients, were found eligible for our meta-analysis. Indirect pairwise comparison showed differences in surgery time between BipolEP and HolEP (MD - 16.72 min., 95% CI - 27.75 to - 5.69) and DiLEP and HoLEP (MD - 22.41 min., 95% CI - 39.43 to - 5.39). No differences in the amount of resected prostatic tissue, major and minor complications and postoperative catheterization time were found. The odds for blood transfusions were threefold higher for BipolEP than for HoLEP (OR 3.27, 95% CI 1.02-10.5). The difference was not statistically significant when comparing prospective trials and matched-pair analysis only (OR 3.25, 95% CI 0.94-11.18). The Qmax 12 months after surgery was 2 ml/sec. higher for BipolEP than for DiLEP (MD 2.00, 95% CI 0.17-3.84) and 1.94 ml/sec. lower for DiLEP than for HoLEP (MD - 1.94, 95% CI - 3.65 to - 0.22).
Conclusion:
The energy source used for EEP has an impact on the intervention itself. BipolEP promotes surgical efficiency; laser techniques lower the risk of bleeding.
Registry:
This meta-analysis is registered in the PROSPERO international prospective register registry with the registration number CRD42020205836.
Related Concept Videos
Endoscopic Procedures V: ERCP
Patient...
Endoscopic Procedures III: Video Capsule Endoscopy
Urologic Endoscopic Procedure: Cystoscopic Examination
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...