A comprehensive formula for computing corrected QT intervals in patients with wide QRS
Related Experiment Video
Updated: Nov 6, 2025

In Vivo Surface Electrocardiography for Adult Zebrafish
Published on: August 1, 2019
Santiago Colunga1, Valeria Rolle2, Cesar Moris1
1Cardiology Department, Hospital Universitario Central de Asturias, Oviedo, Spain; Instituto de Investigación Sanitaria del Principado de Asturias, Oviedo, Spain.
Background:
There is increasing interest in developing appropriate methods for correction of the QT intervals in patients with prolonged depolarization of the ventricles. From an experimental model of controlled heart rate and QRS widening, we aimed to develop a new formula with better performance.
Methods:
After exclusions, incremental pacing was performed (AAI mode; 50-120 bpm) in 17 patients admitted for self-expanding aortic valve implantation in two different phases: before and immediately after the release of the prosthesis. Mixed linear models were built to predict variation in QRS and JT intervals, and subsequently calculate the corrected QT (QTQRS-C). Internal and external validation on a new cohort of 48 patients was performed.
Results:
Significant QRS widening (32.5 ms; CI95%:31.5-33.6) and QT prolongation (35.4 ms; CI95%:33.4-37.4) was observed after the release of the prosthesis. The best fit formula was computed as QTQRS-C = QTmeasured - (1.058*QRSmeasured - 108.397) - (0.0496*JTmeasured - 11.038). Internal validation provided a good correlation between measured and predicted QT (Pearson's coefficient:0.76; CI95%:0.70-0.80). In an external cohort (n = 48), the QRS widening was 28.4 ms(CI95%:21.8-35.1) and the JT widening was 16.58 ms(CI95%:8.73-24.4). Compared to other formulas, our proposed formula tends to display better performance as a result of a combination of appropriate correlation (Pearson's:0.75), being the closer to identity line (slope 0.83) and minimizing the relative standard error of the estimates (RSE 0.11).
Conclusions:
We developed a formula with better performance for QT correction in patients with wide QRS.
More Related Videos
08:28Methods for ECG Evaluation of Indicators of Cardiac Risk, and Susceptibility to Aconitine-induced Arrhythmias in Rats Following Status Epilepticus
Published on: April 5, 2011
11:13Electrophysiological Analysis of human Pluripotent Stem Cell-derived Cardiomyocytes hPSC-CMs Using Multi-electrode Arrays MEAs
Published on: May 12, 2017
Related Concept Videos
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Quartile
1; 1; 2; 2; 4; 6; 6.8; 7.2; 8; 8.3; 9; 10; 10; 11.5
The median or second quartile is seven. The lower half of the...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Modified Boxplots
However, the box plot does not tell the reader about outliers - values that lie far from the center of the data. We can modify the standard box and whisker plot to identify the outliers and visualize the actual spread of the data in a sample.
Initially, we calculate the adjusted...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias