Short-term changes in and preoperative factors affecting vaulting after posterior chamber phakic Implantable Collamer
Qiu-Jian Zhu1, Wen-Jing Chen1, Wei-Jian Zhu1
1Department of Ophthalmology, Lixiang Eye Hospital of Soochow University, Jiangsu, 215021, Suzhou, China.
Background:
To describe the very early vault changes in the first month after Implantable Collamer Lens (ICL) implantation and to evaluate the effect of preoperative biometric factors on vault.
Methods:
Eighty-three eyes from eighty-three subjects with complete data who met follow-up requirements were recruited in this retrospective study between May 2019 and March 2020. We quantitatively assessed the postoperative vault at 2 h, 1 day, 1 week, and 1 month following implantation. Associations between the postoperative vault and age, ICL size, spherical equivalent (SE), axial length (AL), central corneal thickness (CCT), flat keratometry (K), steep K, mean K, anterior chamber depth (ACD), crystalline lens thickness (LT), white-to-white (WTW) diameter obtained by three devices, horizontal and vertical sulcus-to-sulcus (STS) diameter, bright and dark pupil sizes (BPS and DPS) and DPS-BPS were investigated using Spearman's correlation analysis and stepwise multiple regression analysis.
Results:
The mean vault values at 2 h, 1 day, 1 week, and 1 month after ICL implantation were 672.05 ± 30.72, 389.15 ± 28.33, 517.23 ± 30.76 and 530.12 ± 30.22 μm, respectively. Significant differences were found in the vault values at 2 h, 1 day and 1 week after the operation. The ICL size (β = 0.942; p < 0.001), followed by horizontal STS (β = -0.517; p < 0.001), crystalline LT (β = -0.376; p < 0.001) and vertical STS (β = -0.257; p = 0.017), significantly influenced the vault at 1 month after the operation. The multiple regression equation was expressed as follows: central vault (µm) = -1369.05 + 657.121 × ICL size- 287.408 × horizontal STS - 432.497 × crystalline LT - 137.33 × vertical STS (adjusted R2 = 0.643).
Conclusions:
After ICL implantation, the vault decreased and then increased, but it did not return to the vault value 2 h after surgery. The ICL size, horizontal and vertical STS and crystalline LT are key factors for predicting postoperative vaulting.
More Related Videos
05:46Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
05:19Author Spotlight: Unraveling the Molecular Mechanisms in PCO and Fibrosis Following Cataract Surgery
Published on: December 1, 2023
Related Concept Videos
Angle Closure Glaucoma: Treatment
Glaucoma: Overview
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...