Related Experiment Video
Updated: Nov 6, 2025

Fully Endoscopic Mitral Valve Repair with Percutaneous Cannulation of Groin Vessels
Published on: May 26, 2023
Mid-term follow-up of percutaneous access for standard and complex EVAR using the ProGlide device
N A Bradley1, P Orawiec1, R Bhat2
1Department of Vascular Surgery, Ninewells Hospital, Dundee, UK.
Objectives:
Endovascular Aneurysm Repair is an established treatment for abdominal aortic aneurysm which requires arterial access via the groin. Most centres perform percutaneous ultrasound-guided access into the common femoral artery for delivery of the stent graft. The profile of endovascular devices necessitates large sheath sizes, therefore formal closure of the arterial puncture site is required. Various percutaneous devices are available, with data lacking on efficacy and mid-term safety profile. We present outcomes from a single centre with the Perclose ProGlide™ (Abbott Vascular Devices, CA, USA) suture-mediated system, using the well described "pre-close" technique.
Materials & Methods:
Data were collected from operative records and electronic medical records. Patients undergoing standard (EVAR) or complex (F/B-EVAR) aneurysm repair between March 2015 and September 2019 were included. Complications were recorded per-patient and per-groin procedure.
Results:
266 patients were included; 182 (68.4%) standard infrarenal EVAR, 84 (31.6%) F/B-EVAR. There were a total of 484 groin procedures performed. Intraoperative Perclose ProGlide™ success was 98.1% (per patient) or 99.0% (per groin procedure). 30-day groin complication rate was 6.1% (per patient) or 3.1% (per groin procedure). There were no pre- or peri-operative factors which predicted the occurrence of groin complications. The rate of groin complications was not related to sheath size.
Conclusions:
Our data support the use of percutaneous access with a pre-close technique for a variety of endovascular aneurysm repair procedures with both large- and small-bore access. The Perclose ProGlide™ system provides excellent mid-term complication-free and reintervention-free outcomes for groin procedures.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Peripheral Artery Disease V: Postoperative Nursing Management
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
Hemodialysis II: Procedure and Complications