Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
Published on: August 30, 2013
43.2K
Robust Subspace Detectors Based on α-Divergence With Application to Detection in Imaging
Summary
This paper introduces robust statistical tests for detecting signals in noisy data. These tests offer adjustable trade-offs between reliability and detection power, outperforming classical methods in challenging environments.
Area of Science:
- Signal processing
- Statistical inference
- Robust statistics
Background:
- Detecting signal subspaces is crucial in various data analysis applications.
- Classical statistical tests can be sensitive to outliers and noise contamination.
- Existing methods may lack adaptability to different noise levels and outlier presence.
Purpose of the Study:
- To develop robust variants of Wald, Rao, and likelihood ratio (LR) tests.
- To enable adjustable trade-offs between test robustness and detection power using a hyperparameter α.
- To provide a unified framework for robust signal detection.
Main Methods:
- Derivation of robust tests using the α-divergence.
- Analysis of asymptotic properties to support the proposed tests.
- Adjustment of robustness and power via a single hyperparameter α.
Main Results:
- Proposed tests demonstrate robustness to outliers, particularly for specific α values.
- Robust LR test shown to be equivalent to the classical LR test or matched subspace detector (MSD) as α approaches 1.
- Numerical experiments validate performance on diverse datasets (fMRI, hyperspectral, SAR).
Conclusions:
- The proposed α-divergence-based tests offer a flexible and robust approach to signal subspace detection.
- These methods provide improved performance in the presence of contaminated Gaussian noise and outliers.
- The adjustable hyperparameter α allows for tailored application across different data types and noise conditions.
Related Concept Videos
Difference from Background: Limit of Detection
7.5K
The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
The LOD indicates the presence or absence...
7.5K
Detection of Black Holes
2.3K
Although black holes were theoretically postulated in the 1920s, they remained outside the domain of observational astronomy until the 1970s.
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
2.3K
Computed Tomography
7.5K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
7.5K
Imaging Studies II: Ultrasonography
111
IntroductionUltrasonography, or renal ultrasound, is a noninvasive medical imaging technique that uses high-frequency sound waves to visualize the kidneys, ureters, bladder, and surrounding tissues.Indications for Urinary System UltrasonographyUrinary system ultrasonography is indicated in various clinical scenarios, such as:Kidney Stones (Urolithiasis): To detect and monitor the size and presence of kidney or urinary tract stones.Hydronephrosis: To assess the dilation of the renal pelvis and...
111
X-ray Imaging
9.2K
German physicist Wilhelm Röntgen (1845–1923) was experimenting with electrical current when he discovered that a mysterious and invisible "ray" would pass through his flesh but leave an outline of his bones on a screen coated with a metal compound. In 1895, Röntgen made the first durable record of the internal parts of a living human: an "X-ray" image (as it came to be called) of his wife’s hand. Scientists worldwide quickly began their own experiments with...
9.2K