Experimental design optimization of simultaneous enantiomeric separation of atenolol and chlorthalidone binary
Rasha M Hassan1, Ola A Saleh1, Aida A El-Azzouny1
1Medicinal and Pharmaceutical Chemistry Department, Pharmaceutical and Drug Industries Research Division, National Research Centre (ID: 60014618), Giza, Egypt.
Abstract:
In this work, enantiomeric separation of a drug combination of two chiral drugs, namely, atenolol and chlorthalidone, is described. Prior investigation of the effect of different variables on the resolution of the enantiomers' peaks and the total run time represented by the retention time of the last eluted peak was conducted using face-centered composite design. Twenty-two experiments were carried out by varying the chiral stationary phase type as a categorical factor and mobile phase composition including the percentage of ethanol and percentage of diethylamine as continuous factors. According to the optimization process, a mobile phase consisting of hexane:ethanol:DEA:TFA (60:40:0.2:0.1%, v/v/v/v) pumped at flow rate 1 ml min-1 onto Lux-Cellulose 2 stationary phase was applied for the chiral separation and quantification of the drug combination at 230 nm. Application of the developed method to the pharmaceutical formulation of this combination was successfully performed, and satisfactory percentage of recoveries was obtained. The method was also fully validated following International Conference on Harmonization (ICH) guidelines. This method could be of high value and relevance for application in quality control laboratories.
More Related Videos
09:12Optimization of Processing of Tiebangchui with Highland Barley Wine Based on the Box-Behnken Design Combined with the Entropy Method
Published on: May 19, 2023
10:14Synthesis and Purification of Iodoaziridines Involving Quantitative Selection of the Optimal Stationary Phase for Chromatography
Published on: May 16, 2014
Related Concept Videos
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Ion-Exchange Chromatography
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Racemic Mixtures and the Resolution of Enantiomers
