High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Solid-phase microextraction- probe electrospray ionization devices for screening and quantitating drugs of abuse in
Milaan Thirukumaran1, Varoon Singh1, Yohei Arao2
1Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada.
Abstract:
Probe electrospray ionization (PESI) is an ambient ionization mass spectrometry technique (AIMS) that is primarily used in qualitative studies, though researchers have recently combined it with sample preparation for the quantitative analysis of various analytes in biological matrices. This study presents a method that integrates solid-phase microextraction with PESI for direct coupling to a triple quadrupole mass spectrometer, and examines its ability to quantitate drugs of abuse. Intra- and inter-probe reproducibility experiments were conducted to assess the stability and reproducibility of the extraction-phase-coated PESI probes (coating length: 2 mm; coating thickness: 6.5 μm). This research is the first documented instance wherein highly sensitive determinations were successfully attained using these microextraction and micro-desorption techniques in conjunction with small volumes of sample and extraction phase. A mixture consisting of IPA/H2O (1/1 v/v) + 0.1% FA was determined to be the optimal desorption solvent for SPME-PESI-MS/MS, as it facilitated high analyte enrichment in a picolitre of the solvent, which acted at the same time as efficient electrospray media. Furthermore, a method of quantifying drugs of abuse in 30 μL of plasma without matrix modification was also developed. This method had an intra-day accuracy within the 80-120% range for all eight drugs of abuse at concentrations of 3, 30, and 90 pg μL-1; the exception to this result was lorazepam at 30 pg μL-1, which had an intra-day accuracy of 122%. The lower limit of quantification (LLOQ) for fentanyl and nordiazepam was pg μL-1; the LLOQ for buprenorphine, codeine, diazepam, lorazepam, and propranolol was 5 pg μL-1; and the LLOQ of oxazepam was 10 pg μL-1.
More Related Videos
07:26A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
07:55Integrated Cell Manipulation Platform Coupled with the Single-probe for Mass Spectrometry Analysis of Drugs and Metabolites in Single Suspension Cells
Published on: June 21, 2019
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
High-Performance Liquid Chromatography: Types of Detectors