Related Experiment Video
Updated: Nov 6, 2025

Ultrasonographic Assessment During Cardiopulmonary Resuscitation
Published on: October 24, 2020
Adequacy of hand positioning by medical personnel during chest compression in a simulation study
Yasuaki Koyama1, Tasuku Matsuyama2, Takako Kainoh1
1Department of Emergency and Critical Care Medicine University of Tsukuba Hospital Tsukuba Ibaraki Japan.
Aim:
During chest compressions (CCs), the hand position at the lower half of the sternum is not strictly maintained, unlike depth or rate. This study was conducted to determine whether medical staff could adequately push at a marked location on the lower half of the sternum, identify where the inappropriate hand position was shifted to, and correct the inappropriate hand position.
Methods:
This simulation-based, prospective single-center study enrolled 44 medical personnel. Pressure and hand position during CC were ascertained using a flexible pressure sensor. The participants were divided into four groups by standing position and the hand in contact with the sternum: right-left (R-l), right-right (R-r), left-right (L-r), and left-left (L-l). We compared the groups and the methods: the manual method (MM), the thenar method, and the hypothenar method (HM).
Results:
Among participants using the MM, 80% did not push adequately at the marked location on the lower half of the sternum; 60%-90% of the inadequate positions were shifted to the hypothenar side. CCs with the HM facilitated stronger pressure, and the position was minimally shifted to the hypothenar side.
Conclusion:
Medical staff could not push at an appropriate position during CCs. Resuscitation courses should be designed to educate personnel on the appropriate position for application of maximal pressure while also evaluating the position during CCs.
Related Concept Videos
Cardiopulmonary Resuscitation I: Adult
Cardiopulmonary Resuscitation II: ACLS Airway Management
Cardiopulmonary Resuscitation III: AED Use
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...