Transradial Access Chemoembolization for Hepatocellular Carcinoma Patients
Published on: September 20, 2020
Application of a rapid exchange extension catheter technique in type B2/C nonocclusive coronary intervention via a
Hong-Chao Wang1, Wei Lu2, Zi-Han Gao1
1Department of Cardiology, The Second Hospital of Hebei Medical University, Shijiazhuang 050000, Hebei Province, China.
Background:
In transradial intervention procedures, poor back-up support and noncoaxial alignment of the guide catheter (GC) may result in failure of the balloon or stent to reach the targeted lesion. Methods to provide extra back-up support using the original GC and wire can improve procedural success with reduced complications. A rapid exchange guide extension catheter provides convenient and efficient back-up support while preserving the initial GC and inserted wire.
Aim:
To evaluate the efficacy and safety of rapid exchange extension catheter in the treatment of type B2/C nonocclusive coronary lesions via the radial access.
Methods:
A total of 135 patients with type B2/C nonocclusive lesions who were treated via the transradial approach were enrolled in the study. The clinical characteristics, indications for use of the rapid exchange extension catheter, and procedural details and results were reviewed and analyzed. All procedure-related complications and major adverse cardiovascular events were recorded during the in-hospital stay and follow-up period.
Results:
The most common indication for the use of a rapid exchange extension catheter was vascular tortuosity (37.8%), followed by heavy calcification (28.9%), long lesions (20.0%), proximal stent (6.7%), in-stent restenosis (5.2%), and coronary origin anomalies (1.5%). The following technologies failed in passing targeted lesions before delivering the rapid exchange catheter: Multiple predilatation technique (57%), buddy wire technique (33.4%), balloon anchoring technique (5.9%), and cutting balloon modification (3.7%). The mean depth of the extension catheter intubation was 20.56 ± 13.05 mm, and the mean rapid exchange catheter service time was 18.9 ± 9.7 min. The mean length and diameter of stents were 33.5 ± 14.4 mm and 2.75 ± 0.45 mm, respectively. The total rate of technique success (balloon or stent successful crossing of the target lesion with this technique) was 94.8%.
Conclusion:
The rapid exchange extension catheter technique showed acceptable safety and efficacy in the transradial coronary interventions of type B2/C nonocclusive coronary lesions. We recommend this technique to assist in complex lesion intervention via radial access.
More Related Videos
06:04Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
06:39Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease
Published on: February 18, 2020
Related Concept Videos
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization III: Left Heart Catheterization
Peripheral Artery Disease III: Interprofessional Care