Background:
Pancreatic exocrine insufficiency (PEI) is associated with the outcome of pancreatic disease. However, there is no method for assessing PEI that can be used noninvasively and easily for outpatient. It has been reported that changes in intestinal bacteria caused by PEI may increase breath hydrogen concentration (BHC) levels during glucose or lactose loading. We have evaluated the usefulness of fasting breath hydrogen concentration (FBHC) measurement without glucose loading for the evaluation of PEI.
Methods:
Sixty patients underwent FBHC measurement, BT-PABA testing, and microbiome analysis. They were classified into PEI group (PABA excretion rate < 73.4%, n = 30) and non-PEI group (n = 30). The FBHC of the two groups were compared, and the diagnostic ability of PEI by them was evaluated. The 16 s rRNA (V3-V4) from fecal samples was analyzed by MiSeq.
Results:
FBHC levels was higher in the PEI group 15.70 (1.4 to 77.0) ppm than in the non-PEI group 2.80 (0.7 to 28.2) ppm (P < 0.0001). FBHC was negatively correlated with PABA excretion rate (r = - 0.523, P < 0.001). The cutoff value of FBHC of 10.7 ppm (95% CI: 0.678-0.913, P < 0.001) showed a sensitivity of 73.3% and specificity of 83.3% for PEI diagnosis. In the PEI group, there was a significant increase of relative abundance of phylum Firmicutes (P < 0.05) and the genus Clostridium (P < 0.05).
Conclusion:
FBHC shows good potential as a simple and repeatable test for the diagnosis of PEI. The elevated FBHC levels may be caused by hydrogen-producing bacteria such as Clostridium.
More Related Videos
12:24Assessment of Gastric Emptying in Non-obese Diabetic Mice Using a [13C]-octanoic Acid Breath Test
Published on: March 23, 2013
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Related Concept Videos
Serum Laboratory Studies, Stool Test, Breath Test
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History