Related Experiment Video
Updated: Nov 6, 2025

Development of an In Vitro Ocular Platform to Test Contact Lenses
Published on: April 6, 2016
Factors Affecting Microbial Contamination on the Back Surface of Worn Soft Contact Lenses
Jacqueline Tan, Jaya Sowjanya Siddireddy1, Katherine Wong1
1Faculty of Medicine and Health, School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia.
Significance:
The results of this study demonstrate that Smart Touch Technology packaging, which is designed to reduce and simplify contact lens handling before insertion, is effective in reducing the frequency of bacterial contamination of the back surface of contact lenses after short-term wear.
Purpose:
The purpose of this study was to investigate the effect of lens packaging type, chelating agent, and finger contamination on microbial contamination on the back surface of worn soft contact lenses.
Methods:
Twenty-five subjects completed each contralateral lens wear comparison in this randomized study: Smart Touch Technology versus conventional blister packaging for (1) silicone hydrogel lenses with ethylenediaminetetraacetic acid (EDTA) and (2) hydrogel lenses without EDTA in the packaging, and (3) silicone hydrogel lenses without EDTA versus hydrogel lenses with EDTA both in Smart Touch Technology packaging. Participants washed hands, underwent finger swabs, and inserted the lenses. After 45 minutes, lenses were removed aseptically and the posterior lens surfaces cultured.
Results:
Thirty-eight subjects (average age, 30.9 ± 12.5 years) participated in this study. Overall, the level of back surface contamination was low for both lens materials, ranging from 0 to 43 colony-forming unit (CFU)/lens for the silicone hydrogel and 0 to 17 CFU/lens for the hydrogel lenses. The proportion of lenses with zero back surface contamination ranged from 16 to 64% for silicone hydrogel lenses and 28 to 64% for hydrogel lenses. Contact lenses from conventional packaging containing EDTA had 3.38 times increased risk (95% confidence interval [CI], 1.02 to 11.11; P = .05) of contamination being present compared with lenses from Smart Touch packaging with EDTA. Contact lenses from conventional packaging without EDTA had 3.4 times increased risk (95% CI, 1.02 to 11.36; P = .05) of contamination being present compared with Smart Touch packaging without EDTA, and silicone hydrogel lenses had a 6.28 times increased risk (95% CI, 1.65 to 23.81; P = .007) of contamination being present compared with hydrogels. The median (interquartile range) number of bacteria isolated from fingers used to perform lens insertion after handwashing but before lens insertion was not significantly different between the silicone hydrogel and hydrogel lenses (63.7 [204.2] vs. 59 [84.5], P = .09). Finger contamination was not significantly associated with lens contamination in the presence or absence of EDTA.
Conclusions:
Smart Touch Technology packaging was effective in reducing the proportion of contaminated lenses. Although silicone hydrogel lenses were more likely to be contaminated, the presence of EDTA ameliorated this effect. Finger contamination was not associated with lens contamination.
Related Concept Videos
Surface Membrane Barriers
The outer layer of the skin, the epidermis, is a robust barrier comprising layers of closely packed keratinized cells. This dense arrangement prevents microbes from penetrating the body. The periodic shedding of epidermal cells...
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin...
Factors Influencing Microbial Growth: Osmolarity
Antimicrobial Effectiveness
Hand hygiene
Hand washing...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration