Effect of intravenous oxycodone on the physiologic responses to extubation following general anesthesia
Menglu Jiang1, Jiawei Ji1, Xin Li1
1Department of Anesthesiology, Wuxi 9th Affiliated Hospital of Soochow University, No. 999 Liangxi Rd, 214062, Wuxi, China.
Background:
Endotracheal intubation and extubation may cause undesirable hemodynamic changes. Intravenous oxycodone has recently been introduced and used for relieving hemodynamic alterations in response to intubation, but there is insufficient information regarding its application in stabilizing hemodynamics during extubation in the patients emerging from general anesthesia.
Methods:
One hundred patients, who had undergone assorted laparoscopic surgeries under general anesthesia, were randomly assigned to Control group (saline injection, 50 cases) and Study group (intravenous injection of 0.08 mg/kg oxycodone immediately after completion of the surgical procedure, 50 cases). Blood pressure, heart rate, blood oxygen saturation (SpO2) as well as blood concentrations of epinephrine, norepinephrine, and cortisol were recorded or measured immediately before extubation (T0), during extubation (T1), as well as one minute (T2), 5 min (T3), and 10 min after extubation (T4). In addition, coughing and restlessness, time of eye-opening, and duration from completing surgery to extubation as well as Ramsay Sedation Scale were analyzed.
Results:
Blood pressure and heart rate as well as blood concentrations of epinephrine, norepinephrine, and cortisol were significantly higher in the Control group compared with the Study group at the time of extubation as well as 1, 5, and 10 min after extubation (P < 0.05). When the patients emerged from general anesthesia, 70 % of the Control group had cough, which was significantly higher than that of Study group (40 %, P < 0.05). Significantly higher number of patients manifested restlessness in the Control group before (40 %) and after extubation (20 %) compared with that in the Study group (20 and 2 %, respectively, P < 0.05). In addition, patients of Control group had lower Ramsay score at extubation (1.7 ± 0.7) as well as 30 min after extubation (2.4 ± 0.9) compared to that of the patients of Study group (2.2 ± 0.9, and 3.0 ± 0.8, respectively, P = 0.003 and 0.001).
Conclusions:
Intravenous oxycodone attenuated alterations of hemodynamics and blood hormones associated with extubation during emergence from general anesthesia.
Trial Registration:
Chinese Clinical Trial Registry: ChiCTR2000040370 (registration date: 11-28-2020) "'retrospectively registered".
More Related Videos
08:49Assessing Changes in Volatile General Anesthetic Sensitivity of Mice after Local or Systemic Pharmacological Intervention
Published on: October 16, 2013
06:57Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
Related Concept Videos
Parenteral Anesthetics: Overview
Stages of General Anesthesia
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Inhalational Anesthetics: Overview