Aim:
Thyroid stimulating hormone (TSH) assays provided by Abbott Laboratories and Roche Diagnostics are used by approximately 75% of laboratories in the UK. We assessed the potential impact of Abbott and Roche TSH assay differences on the biochemical assessment of levothyroxine replacement in primary hypothyroidism.
Method:
Samples from 100 consecutive primary care patients (83 women, median age 64 years, IQR 51-73 years) with primary hypothyroidism on adequate levothyroxine based on an Abbott Architect TSH in the reference range were analysed for TSH on Roche cobas within 24 hours. The Abbott and Roche TSH results were compared. Over 1 year, TSH results from patients in primary care from the laboratories with Abbott and Roche methods were compared.
Results:
The median (IQR) Roche TSH (2.5 (1.3-3.6) mIU/L) was 30%±10% higher (p<0.001) than Abbott TSH (1.9 (1.1-2.6) mIU/L). Although all Abbott TSH results were in the Abbott specific reference range, 14 patients (14%) had Roche TSH results above the Roche specific reference range. In the 1 year gather, Roche TSH (1.9 (1.3-2.9) mIU/L, n=103 932) results were higher (p<0.001) than Abbott TSH (1.5 (1.0-2.2) mIU/L, n=1 10 544) results. The TSH results were above their assay-specific upper reference limit in 10.7% of Roche results and 4.2% of Abbott results.
Conclusion:
Biochemical assessment of levothyroxine replacement may be dependent on the type of TSH assay. Laboratorians and clinicians should be aware that the lack of harmonisation between TSH methods and their assay-specific reference ranges may potentially lead to different patient management decisions. We suggest lot verification in laboratories should include processes to identify cumulative drift in assay performance.
Related Concept Videos
Synthesis and Regulation of Thyroid Hormones
Upon reaching the thyroid gland, TSH stimulates the follicular cells' active uptake of iodide ions from the blood. The ions diffuse to the apical surface of the cells and are oxidized to iodine. The...
Therapeutic Drug Monitoring: Drug Analysis Methods
Functions of Thyroid Hormones
TH is indispensable for the normal development and maturation of the skeletal, muscular, and nervous systems during fetal and childhood growth. It facilitates bone mineral turnover and regulates protein synthesis in developing tissues, contributing significantly to overall growth and...
Bioequivalence of Drugs: Drugs with Multiple Indications
Therapeutic Drug Monitoring: Affecting Factors
Effect of Hepatic Disease on Pharmacokinetics: Pathophysiologic Assessment and Liver Function Test