Validation of a Deep Learning Tool in the Detection of Intracranial Hemorrhage and Large Vessel Occlusion

Joel McLouth1, Sebastian Elstrott1, Yasmina Chaibi2

  • 1Department of Radiological Sciences, University of California, Irvine, Irvine, CA, United States.

Insights

This study validates a deep learning tool for detecting intracranial hemorrhage (ICH) and large vessel occlusion (LVO) across diverse US hospitals. The AI tool shows high accuracy, aiding radiologists in identifying critical findings in various clinical settings.

Area of Science:

  • Neuroradiology
  • Artificial Intelligence in Medicine
  • Medical Imaging Analysis

Background:

  • Machine learning algorithms show promise for detecting intracranial hemorrhage (ICH) and large vessel occlusion (LVO).
  • Generalizability of these algorithms is often limited by geographic bias in study data.
  • Validation across diverse healthcare settings is crucial for clinical adoption.

Purpose of the Study:

  • To validate a commercial deep learning tool for detecting both ICH and LVO.
  • To assess the tool's performance across multiple hospital sites and CT vendors in the U.S.
  • To evaluate the tool's ability to detect and quantify various subtypes and volumes of ICH and LVO.

Main Methods:

  • Retrospective, multicenter study using anonymized CT and CT angiography data.
  • Analysis of 814 non-contrast CT cases for ICH and 378 CT angiography cases for LVO.
  • Ground truth established by two board-certified neuroradiologists; performance assessed across multiple vendors and hospitals.

Main Results:

  • ICH detection: 95.6% accuracy, 91.4% sensitivity, 97.5% specificity. High true positive rates for various ICH subtypes and volumes (5-25 mL and >25 mL).
  • LVO detection: 98.1% accuracy, 98.1% sensitivity, 98.2% specificity.
  • Sub-analysis of LVO detection in specific arterial segments showed high accuracy (97.0%), sensitivity (94.3%), and specificity (97.4%).

Conclusions:

  • Deep learning tools are effective for detecting ICH and LVO across diverse hospital systems.
  • The validated tool can assist radiologists in identifying emergent findings in various practice settings.
  • Limitations include detection of small ICH and distal M2 occlusions, warranting further refinement.