Related Experiment Video
Updated: Nov 5, 2025

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Relationship between indexed aortic area and aortic diameter in bicuspid aortic valve aortopathy: A retrospective
Metesh Acharya1, Oswaldo Valencia1, Mark Edsell2
1Department of Cardiothoracic Surgery, St. George's Hospital, London, UK.
Background:
Aortic dissection is a life-threatening complication of bicuspid aortic valve (BAV)-associated aortopathy. In these populations, whilst prophylactic replacement of proximal thoracic aortic aneurysms (TAAs) is generally recommended at threshold diameters ≥5.5 cm, dissection may occur in smaller aortas. An alternative size-based parameter, the cross-sectional aortic area/patient height ratio (indexed aortic area, IAA), correlates with increased dissection risk at abnormal values > 10 cm2/m. We sought to assess the utility of the IAA in identifying at-risk BAV-associated TAAs with abnormal IAA, albeit with sub-threshold aortic diameter.
Materials And Methods:
We retrospectively identified 69 patients with BAV-associated TAAs who underwent surgical repair between 2010 and 2016. Aortic diameter was measured on pre-operative imaging, and IAA calculated, at the mid-sinus of Valsalva, sino-tubular junction and mid-ascending aorta for each patient. We determined proportions of aneurysms with IAA >10 cm2/m, median IAAs corresponding to aortic diameters <4.0 cm, 4.0-4.5 cm, 4.5-5.0 cm, 5.0-5.5 cm and >5.5 cm, and median aortic diameters corresponding to an abnormal IAA.
Results:
50.9%, 12.5% and 64.6% of aneurysms at the sinus of Valsalva, sino-tubular junction and mid-ascending aorta, respectively, had an abnormal IAA. 51.9% and 88.9% of patients with aortic diameter 4.5-5.0 cm and 5.0-5.5 cm, respectively, had an abnormal IAA. In aneurysms with abnormal IAA involving the sinus of Valsalva, sino-tubular junction, and mid-ascending aorta, median aortic diameters were 4.98 cm, 5.04 cm and 5.11 cm, respectively. Overall, 57/72 (79.2%) at-risk aneurysms with IAA >10 cm2/m had diameters smaller than the 5.5 cm guideline cut-off for surgical intervention.
Conclusion:
Significant proportions of BAV-associated TAAs are at increased risk of aortic dissection attending an IAA >10 cm2/m, whilst not fulfilling the size criteria indicating aortic surgery in contemporary guidelines. Further analysis of IAA in larger BAV cohorts is necessary to clarify its role in patient selection and optimal timing for prophylactic aortic replacement.
More Related Videos
04:48Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
06:51Author Spotlight: Development of a Minimally Invasive Large-Animal Model for Reliable and Reproducible Cardiovascular Research
Published on: October 20, 2023
Related Concept Videos
Aortic Regurgitation I: Introduction
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Aortic Regurgitation III: Medical Management
Aneurysm III: Interprofessional Care
Aneurysm II: Clinical Manifestations and Diagnostic Studies