Innovation in Permanent Pacemaker's Implantation Technique: Trans-Axillary Approach
Bakhtawar Shah1, Muhammad Amir Niaz2, Shahab Saidullah3
1Division of Clinical Cardiac Electrophysiology, Department of Cardiology, Hayatabad Medical Complex, Peshawar, PAK.
Introduction:
Permanent pacemakers' (PPM) implantation is an integral part of electrophysiology and general cardiology. The implantation technique has evolved a lot since the first implantation. Several innovations have been undertaken to improve the effectiveness, life of the transplant, and patient outcomes. In this study, we introduced a new implantation technique to improve the procedure and possibly reduce the rate of complication.
Methods:
This study was conducted from January 2016 to February 2017 in Hayatabad Medical Complex, Peshawar. Patients destined for implantation of PPM based on a clinical treatment plan, after proper explanation of the procedure, were brought to the catheterization laboratory. Venogram of the upper limb performed. Patients were scrubbed and draped. The axillary vein was approached via the Seldinger technique. About 2 to 3 cm superolateral to the puncture site, a skin incision was made and subcutaneous pocket constructed, and a guidewire external end was pulled in from inside the pocket keeping the venous end at the place. Subsequently, in a routine way, lead was placed, secured and the wound was closed in layers.
Results:
A total of 690 PPM were implanted under the study. About 290 devices were implanted in the conventional way and 380 devices via the trans-axillary approach. The mean implantation time was less than 30 minutes via the trans-axillary approach. Immediate and delayed complications of the procedure were minimal.
Conclusion:
Trans-axillary approach holds some significant advantages over the conventional technique. The subcutaneous pocket and venous puncture successfully reduce the burden of foreign material, minimize the tension on the wound, shorten implantation time and reduce the chances of erosion of the device.