Accuracy and Reliability of Pulse O2 Saturation Measured by a Wrist-worn Oximeter
Eric Hermand1,2, Clemence Coll3, Jean-Paul Richalet2
1Univ. Littoral Côte d'Opale, Univ. Artois, Univ. Lille, CHU LIlle, ULR 7369 - URePSSS - Unité de Recherche Pluridisciplinaire Sport Santé Société, F-59140 Dunkerque, France.
Abstract:
This study aims to evaluate the accuracy of the Garmin Forerunner 245 heart rate (HR) and pulse O2 saturation (SpO2) sensors compared with electrocardiogram and medical oximeter, from sea level to high altitude. Ten healthy subjects underwent five tests in normoxia and hypoxia (simulated altitudes from 3000 to 5500 m), consisting in a 5-min rest phase, followed by 5-min of mild exercise. Absolute error (±10 bpm for HR and ±3% for SpO2, around criterion) and intraclass correlations (ICC) were calculated. Error rates for HR remained under 10%, except at 3000 m, and ICCs evidenced a good reliability between Garmin and criterion. Overall SpO2 was higher than criterion (P<0.001) with a >50% error rate (>80% above 4800 m), and a poor reliability with criterion. The Garmin device displayed acceptable HR data at rest and exercise for all altitudes, but failed to provide trustworthy SpO2 values, especially at high altitude, where a pronounced arterial O2 desaturation could lead to acute mountain sickness in hypoxia-sensitive subjects, and its life-threatening complications; moreover, readings of overestimated SpO2 values might induce trekkers into further hazardous behavior by pursuing an ascent while being already at risk. Therefore, its use to assess SpO2 should be proscribed in altitude for acclimatization evaluation.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse
The pulse serves as a clinical...


