Related Experiment Video
Updated: Nov 5, 2025

Dispersion of Nanomaterials in Aqueous Media: Towards Protocol Optimization
Published on: December 25, 2017
Simulation of the distribution of astatine-211 solution dispersion in a lab room
Hitoshi Kubo1,2, Kazuhiro Takahashi2, Saki Shimoyama2
1Department of Radiological Sciences, School of Health Sciences.
Objective:
This study aimed to evaluate the distribution of Astatine-211 (211At) solution dispersion in a small animal cage using autoradiography imaging to simulate the dispersion of 211At in a lab room to eventually prevent user's risk of internal exposure in terms of radiation safety.
Methods:
211At radiation sources with two chemical properties (Na211At and Free 211At) were prepared. The solutions of 211At were placed onto a dish with paper, and then, it was placed in a small animal cage for 3 h. After removing the dish, an imaging plate with attaching reference sources was placed at four walls of the cage for 15 h in a lead box. Imaging plates were read, and all pixel data were calculated using Microsoft Excel 2016 to obtain three-dimensional (3D) distribution. Calculated results were depicted using a 3D sphere model.
Results:
The mean activity of Free 211At was 2.3 times higher than that of Na211At on all autoradiography images. In the cage, the shape of the dispersion of Na211At was almost homogeneous, whereas that of Free 211At was more heterogeneous.
Conclusion:
We found that the solution of 211At vaporized naturally and was distributed heterogeneously in the cage, and the chemical properties of 211At influenced their behaviors. These results must be considered to minimize the risks of radiation safety.
More Related Videos
09:56Adapting Taylor Dispersion to Measure the Dispersion Coefficient of Electrolyte Solutions via an Accessible Microfluidic Setup
Published on: October 7, 2025
10:36Stress Distribution During Cold Compression of Rocks and Mineral Aggregates Using Synchrotron-based X-Ray Diffraction
Published on: May 20, 2018
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Distribution and Dispersion
Atomic Emission Spectroscopy: Lab
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Atomic Absorption Spectroscopy: Atomization Methods
Maxwell-Boltzmann Distribution: Problem Solving
This distribution function f(v) is defined by saying that the expected number N (v1,v2) of particles with speeds between v1 and v2 is given by