Near infrared spectral calibration model transfer without standards by screening spectral points with scale invariant
Lijun Ni1, Haixia Chen1, Shijun Hong1
1College of Chemistry and Molecular Engineering, East China University of Science and Technology, Shanghai, 200237, China.
Abstract:
In order to realize calibration model transfer of near infrared (NIR) spectra without standards, scale invariant feature transform (SIFT) algorithm was applied to extract characteristic spectral points of NIR spectra in this study. Three sets of spectral points were selected by SIFT from the spectra of precision detection (SPD) of a radix scutellariae sample by continuously testing the sample three times. Aiming at obtaining high consistency of the three sets, the orthogonal table L9 (34) was used to optimize the parameters of SIFT. Basing on the NIR spectra of several representative radix scutellariae samples, a series of spectral point sets were screened by SIFT with the optimized parameters. Three methods of further treating the spectral points sets to optimize the combination of the spectral points and provided three spectral point sets, which were recorded as Ui, Uu and Uur, respectively. The partial least square (PLS) calibration models for predicting baicalin content of radix scutellariae were built on whole wavelengths, Ui, Uu and Uur at different number of latent variables (nLVs), respectively. Compared with other PLS models, the models of SIFTur-PLS built on Uur, which was obtained by taking union of the firstly selected spectral point sets, then eliminating the points with high deviance of SPD and those with high correlativity from the union, are most robust and always give lower or lowest prediction errors for both master and slave samples at many nLVs. It is a good way to filter stable, highly independent and characteristic spectral points to build robust PLS calibration models by combining SIFT algorithm with standard deviance analysis of SPD and correlative analysis. The models can be directly shared by the slave instrument, without needing transfer sets, and without requiring to correct the spectra of slave instruments or spectral calibration models.
More Related Videos
11:57Three-dimensional Super Resolution Microscopy of F-actin Filaments by Interferometric PhotoActivated Localization Microscopy iPALM
Published on: December 1, 2016
11:05High-definition Fourier Transform Infrared FT-IR Spectroscopic Imaging of Human Tissue Sections towards Improving Pathology
Published on: January 21, 2015
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Calibration Curves: Correlation Coefficient
IR Frequency Region: Fingerprint Region
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
IR Spectrometers