Mark C DeLano1, Maria Vittoria Spampinato2, Eric Y Chang3
1Spectrum Health System, Advanced Radiology Services PC, Division of Radiology and Biomedical Imaging, College of Human Medicine, Michigan State University, Michigan, USA.
Background:
Concerns over gadolinium (Gd) retention encourage the use of lower Gd doses. However, lower Gd doses may compromise imaging performance. Higher relaxivity gadobenate may be suited to reduced dose protocols.
Purpose:
To compare 0.05 mmol/kg and 0.1 mmol/kg gadobenate in patients undergoing enhanced MRI of the central nervous system (CNS).
Study Type:
Retrospective, multicenter.
Population:
Three hundred and fifty-two patients receiving 0.05 (n = 181) or 0.1 (n = 171) mmol/kg gadobenate.
Field Strength/Sequences:
1.5 T and 3.0 T/precontrast and postcontrast T1-weighted spin echo/fast spin echo (SE/FSE) and/or gradient echo/fast field echo (GRE/FFE); precontrast T2-weighted FSE and T2-FLAIR.
Assessment:
Images of patients with extra-axial lesions at 1.5 T or any CNS lesion at 3.0 T were reviewed by three blinded, independent neuroradiologists for qualitative (lesion border delineation, internal morphology visualization, contrast enhancement; scores from 1 = poor to 4 = excellent) and quantitative (lesion-to-brain ratio [LBR], contrast-to-noise ratio [CNR]; SI measurements at regions-of-interest on lesion and normal parenchyma) enhancement measures. Noninferiority of 0.05 mmol/kg gadobenate was determined for each qualitative endpoint if the lower limit of the 95% confidence interval (CI) for the difference in precontrast + postcontrast means was above a noninferiority margin of -0.4.
Statistical Tests:
Student's t-test for comparison of mean qualitative endpoint scores, Wilcoxon signed rank test for comparison of LBR and CNR values; Wilcoxon rank sum test for comparison of SI changes. Tests were significant for P < 0.05.
Results:
The mean change from precontrast to precontrast + postcontrast was significant for all endpoints. Readers 1, 2, and 3 evaluated 304, 225, and 249 lesions for 0.05 mmol/kg gadobenate, and 382, 309, and 298 lesions for 0.1 mmol/kg gadobenate. The lower limit of the 95% CI was above -0.4 for all comparisons. Significantly, higher LBR and CNR was observed with the higher dose.
Data Conclusion:
0.05 mmol/kg gadobenate was noninferior to 0.1 mmol/kg gadobenate for lesion visualization.
Evidence Level:
2 TECHNICAL EFFICACY: Stage 3.
More Related Videos
11:27Preparation and In Vitro Characterization of Dendrimer-based Contrast Agents for Magnetic Resonance Imaging
Published on: December 4, 2016
10:27In Vivo Morphometric Analysis of Human Cranial Nerves Using Magnetic Resonance Imaging in Menière's Disease Ears and Normal Hearing Ears
Published on: February 21, 2018
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Magnetic Resonance Imaging
Drug Accumulation During Multiple Dosing: Intermittent IV Infusions
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
Bioavailability Study Design: Single Versus Multiple Dose Studies