Related Experiment Video
Updated: Nov 4, 2025

Adjunctive Diode Laser Therapy and Probiotic Lactobacillus Therapy in the Treatment of Periodontitis and Peri-Implant Disease
Published on: May 9, 2022
Clinical comparison of instrumentation systems for periodontal debridement: A randomized clinical trial
Rosario Puglisi1, Antonio Santos1, Angels Pujol1
1Department of Periodontology, Universitat Internacional de Catalunya, Barcelona, Spain.
Objective:
To compare clinical efficacy, chairside time and post-treatment hypersensitivity of four instruments used for subgingival periodontal debridement.
Materials & Methods:
Seventeen patients with stage II and III periodontitis were enrolled in this randomized clinical trial using a split-mouth design. Quadrants were randomly divided into four treatment groups: Group A: Gracey curettes-Hu-Friedy® ; Group B: piezoelectric ultrasonic (Satelec® ) with No.1S insert; Group C: diamond burs 40 µm (Intensiv Perioset® ); and Group D: piezosurgery ultrasonic (Mectron® ) with PP1 insert. Clinical outcomes, chairside time and hypersensitivity were assessed at 1, 2, 4 and 8 weeks after treatment. The primary outcome variable was improvement in clinical attachment level.
Results:
At 8 weeks post-treatment, Gracey curettes, piezoelectric ultrasonic (Satelec® ) and piezosurgery ultrasonic (Mectron® ) were statistically more effective than diamond burs in increasing attachment level and reducing probing pocket depth. Comparison of piezoelectric ultrasonic (Satelec® ) and piezosurgery ultrasonic (Mectron® ) with the other instruments showed a statistical difference (p < 0.001) in chairside time. Regarding post-treatment hypersensitivity, no statistical differences were observed in any of the groups.
Conclusions:
Gracey curettes, piezoelectric ultrasonic (Satelec® ) and piezosurgery ultrasonic (Mectron® ) were clinically more effective than diamond burs 40 µm. The ultrasonic instruments showed a significant reduction in chairside time.