Related Experiment Video
Updated: Sep 9, 2026

An Air-liquid Interface Bronchial Epithelial Model for Realistic, Repeated Inhalation Exposure to Airborne Particles for Toxicity Testing
Published on: May 13, 2020
Asbestos-contaminated drinking water: its impact on household air
J S Webber1, S Syrotynski, M V King
1Wadsworth Center for Laboratories and Research, New York State Department of Health, Albany 12201-0509.
Abstract:
Asbestos contamination in excess of 10 billion fibers per liter was detected in a community's drinking water. To assess the possibility of waterborne asbestos becoming airborne, air samples were collected from impacted houses receiving contaminated water from three control houses. Collected within each house were three samples on 0.6-micrometer-pore Nuclepore filters and three samples on 0.8-micrometer-pore Millipore filters. In addition, bulk samples of suspect material and water samples were collected. Mean waterborne asbestos concentrations were 24 million fibers per liter (MFL) in the impacted houses versus only 1.1 MFL in the control houses. Transmission electron microscopy revealed that airborne asbestos concentrations were highest in impacted houses, with airborne asbestos concentrations positively correlated with waterborne concentrations. For fiber and mass measurements on both filter types, airborne asbestos concentrations were significantly higher in the impacted houses: mean concentrations in impacted houses were 0.12 fibers/cm3 and 1.7 ng/m3 on Nuclepore filters and 0.053 fibers/cm3 and 2.3 ng/m3 on Millipore filters versus only 0.037 fibers/cm3 and 0.31 ng/m3 on Nuclepore filters and 0.0077 fibers/cm3 and 0.14 ng/m3 on Millipore filters from control houses. Also detected in the air samples from impacted houses were clusters of chrysotile, often with several hundreds of fibers. When estimates of these individual fibers were added to the total fiber count, the difference between the impacted and control houses became even greater. The increased concentrations in impacted houses were due primarily to short (less than 1 micrometer) fibers. Bulk samples did not reveal likely materials within the impacted houses to account for these differences. Thus high levels of waterborne asbestos were apparently the source of increased concentrations of airborne asbestos within these houses.
More Related Videos
09:33Visualizing Field Data Collection Procedures of Exposure and Biomarker Assessments for the Household Air Pollution Intervention Network Trial in India
Published on: December 23, 2022
05:18Measuring Carbon Content in Airway Macrophages Exposed to Carbon-Containing Particulate Matters
Published on: July 12, 2024
Related Concept Videos
The Periodic Table and Organismal Elements
Pulmonary Tuberculosis I
Causative Organism
The primary infectious agent causing tuberculosis is Mycobacterium tuberculosis, a slow-growing, acid-fast, aerobic rod that exhibits sensitivity to heat and ultraviolet light. Instances of Mycobacterium bovis and Mycobacterium avium contributing to the development of TB infection are rare.
Mode of...
Asthma-I: Introduction
Acid Mine Drainage
Inhalation Anthrax
Asthma I: Introduction