Related Experiment Video
Updated: Nov 4, 2025

Real-Time Monitoring of Neurocritical Patients with Diffuse Optical Spectroscopies
Published on: November 19, 2020
Real-time continuous measurement of intraoperative trace exhaled propofol by planar differential mobility
Yang Li1, Dandan Jiang, Kun Zhao
1CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, Liaoning 116023, People's Republic of China. hli@dicp.ac.cn.
Abstract:
In order to study anesthetic pharmacokinetics and adequately adjust the anaesthesia depth of patients, real-time measurement of the intraoperative exhaled propofol concentration is of significant importance for anaesthetists. Although a series of analytical techniques and methods have been developed for the detection of exhaled propofol, differential mobility spectrometry (DMS) with the advantages of a much smaller instrument, faster response time and cheaper cost shows great potential for the point of care in the operating room. In this paper, a planar DMS was constructed for real-time continuous measurement of trace propofol in exhaled air. The effects of DMS parameters, such as the radio frequency voltage, the drift gas flow rate and the sampling flow rate of exhaled air on the propofol measurement under high humidity conditions were carefully investigated and discussed. Under the optimum experimental conditions, the limit of detection (LOD) for propofol was achieved in ppbv with a linear range of 0.5 to 25 ppbv, both of which meet clinical requirements. Finally, the planar DMS was performed on a patient undergoing thyroidectomy surgery to real-time monitor the intraoperative exhaled propofol, which demonstrated the capability of DMS for sensitive and breath-by-breath continuous measurement of intraoperative trace exhaled propofol.
More Related Videos
08:23Author Spotlight: Advancing Lung Disease Research with Free-Breathing Hyperpolarized Xenon-129 MRI
Published on: November 10, 2023
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...