Residence time and mixing capacity of a rotary tablet press feed frame
Maren Zimmermann1, Markus Thommes1
1Laboratory of Solids Process Engineering, Department of Biochemical and Chemical Engineering, TU Dortmund University, Dortmund, Germany.
Purpose:
Most rotary tablet presses contain a feed frame to provide a continuous powder flow and to feed powder into the dies. The wide residence time distribution (RTD) of these feed frames is problematic, because it negatively affects material traceability in continuous manufacturing. In a rotary tablet press, different machine settings influence the RTD, which is characterized by the mean and the width of the distribution. This study focused on the effects of the rotational speed of the feed frame paddles and the rotary tablet press throughput on the RTD.
Methods:
An in-line UV/Vis measurement method was developed for determining the RTD in the feed frame. A model based on a plug flow and a continuous stirred tank reactor was adapted to model the experimentally determined RTDs. Finally, the mixing capacity of a feed frame was evaluated and correlated with a model parameter of the RTD.
Results:
Overall, the developed UV/Vis measurement method was suitable and could be used to obtain process information regarding content uniformity in real time. The experimentally-determined RTDs were described well by fitting an inverse mixing and a transport time. In addition, a correlation between the location and the shape of measured RTDs and tablet press throughput was found. In contrast, rotational feed frame paddle speed did not affect the RTDs. Split-feeding experiments indicated the mixing capacity of the rotary tablet press feed frame.
Conclusion:
The inverse mixing time can be used as an initial indicator for estimating the mixing capacity.