Related Experiment Video
Updated: Nov 4, 2025

Author Spotlight: Point-of-Care Ultrasound for Gastric Content Assessment and Risk Stratification in Perioperative Care
Published on: September 22, 2023
Prediction of gastric fluid volume by ultrasonography in infants undergoing general anaesthesia
Eun-Hee Kim1, Hee-Chul Yoon1, Ji-Hyun Lee1
1Department of Anaesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea.
Background:
Point-of-care ultrasonography can estimate gastric contents and volume to assess the risk of pulmonary aspiration; however, its use in infants has not been well validated. We aimed to develop a predictive model for estimating gastric fluid volume using ultrasonography in infants.
Methods:
This prospective observational study enrolled 200 infants (≤12 months) undergoing general anaesthesia. After anaesthetic induction, while preserving spontaneous respiration, we measured gastric antral cross-sectional area using ultrasonography in both the supine and right lateral decubitus positions. We then suctioned the gastric content and measured its volume. The primary outcome was development of a gastric fluid volume prediction model with multiple regression analysis. Agreement between the predicted volume and the suctioned volume was evaluated using a Bland-Altman plot.
Results:
Overall, 192 infants were included in the final analysis. Pearson correlation analysis showed that the gastric antral cross-sectional area in the supine (P<0.001; correlation coefficient: 0.667) and right lateral decubitus (P<0.001; correlation coefficient: 0.845) positions and qualitative antral grade (P<0.001; correlation coefficient: 0.581) correlated with suctioned volume. We developed a predictive model: predicted volume (ml)=-3.7+6.5 × (right lateral decubitus cross-sectional area [cm2])-3.9 (supine cross-sectional area [cm2])+1.7 × grade (P<0.01). When comparing the predicted volume and suctioned volume, the mean bias was 0.01 ml kg-1 and the limit of agreement was -0.58 to 0.62 ml kg-1.
Conclusions:
Gastric fluid volume can be estimated using a predictive model based on ultrasonography data in infants.
Clinical Trial Registration:
NCT03155776.
Related Concept Videos
Urodynamic Studies: Uroflowmetry
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Aneurysm IV: Nursing Management
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...
Gastric Emptying
Imaging Studies II: Ultrasonography