This study introduces an intuitive myoelectric hand prosthesis control system using high-density electromyography (HD-EMG) and convolutional neural networks (CNNs). The novel approach significantly reduces setup time and enhances user control for amputees.
Area of Science:
- Biomedical Engineering
- Rehabilitation Technology
- Artificial Intelligence in Medicine
Background:
- Myoelectric hand prostheses aim to restore function for upper-limb amputees but suffer from low user acceptance due to non-intuitive control interfaces.
- Existing systems often require complex calibration and lack responsiveness, hindering seamless integration into daily activities.
Purpose of the Study:
- To develop and evaluate a highly intuitive, responsive, and reliable real-time myoelectric hand prosthesis control strategy.
- To demonstrate the efficacy of a novel human-machine interface for improved prosthesis usability and user acceptance.
Main Methods:
- Utilized surface high-density electromyography (HD-EMG) for muscle signal acquisition.
- Implemented a convolutional neural network (CNN) for adaptive, user-specific gesture recognition.
- Employed a transfer learning approach to minimize training time and simplify calibration.
Main Results:
- Achieved high real-time performance with mean and median positive predictive values (PPV) of 93.43% and 100% for 6 grip modes.
- Demonstrated instant accessibility between gesture states, eliminating mode switching for natural control.
- System latency for correct prediction was under 116 ms.
- Transfer learning reduced setup time to under 10 minutes, an 89.4% improvement over traditional methods.
Conclusions:
- The proposed HD-EMG and CNN-based control strategy offers an intuitive and efficient solution for myoelectric hand prostheses.
- The system's reduced setup time and enhanced responsiveness significantly improve potential user acceptance and rehabilitation outcomes.