Related Experiment Video
Updated: Nov 4, 2025

A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Epidemiology of cardiac implantable electronic device infections: incidence and risk factors
Hui-Chen Han1, Nathaniel M Hawkins1, Charles M Pearman1,2
1Heart Rhythm Services, Division of Cardiology, Department of Medicine, Center for Cardiovascular Innovation, University of British Columbia, Vancouver, British Columbia, Canada.
Insights
Cardiac implantable electronic device (CIED) infections are serious complications impacting patient mortality and requiring re-intervention. Understanding risk factors like technical, patient, and procedural elements is crucial for minimizing CIED infection rates.
Area of Science:
- Cardiology
- Infectious Diseases
- Medical Device Technology
Background:
- Cardiac implantable electronic device (CIED) infections represent a significant cause of morbidity and mortality.
- Infection is the leading CIED complication impacting mortality, re-intervention rates, and hospital stays.
Purpose of the Study:
- To review the epidemiology, incidence, and risk factors associated with CIED infections.
- To provide a comprehensive summary of current knowledge on CIED infection.
Main Methods:
- Review of large prospective studies and contemporary cohort data.
- Analysis of technical, patient, and periprocedural factors influencing infection risk.
Main Results:
- The 12-month CIED infection rate is approximately 1% in large prospective studies.
- Risk factors encompass technical aspects (leads, generator size, prior interventions), patient comorbidities, and procedural elements (peri- and post-operative).
- The PADIT score aids in predicting CIED infection risk.
Conclusions:
- CIED infections are a critical concern with substantial patient impact.
- Identifying and mitigating modifiable risk factors is essential for infection prevention.
- The PADIT score offers a valuable tool for risk stratification in CIED patients.
Abstract:
Cardiac implantable electronic device (CIED) infection is a potentially devastating complication of CIED procedures, causing significant morbidity and mortality for patients. Of all CIED complications, infection has the greatest impact on mortality, requirement for re-intervention and additional hospital treatment days. Based on large prospective studies, the infection rate at 12-months after a CIED procedure is approximately 1%. The risk of CIED infection may be related to several factors which should be considered with regards to risk minimization. These include technical factors, patient factors, and periprocedural factors. Technical factors include the number of leads and size of generator, the absolute number of interventions which have been performed for the patient, and the operative approach. Patient factors include various non-modifiable underlying comorbidities and potentially modifiable transient conditions. Procedural factors include both peri-operative and post-operative factors. The contemporary PADIT score, derived from a large cohort of CIED patients, is useful for the prediction of infection risk. In this review, we summarize the key information regarding epidemiology, incidence and risk factors for CIED infection.
Related Concept Videos
Endocarditis I: Introduction
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin...
Endocarditis III: Medical Management
Bacterial Signaling
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Endocarditis IV: Nursing Management

