Related Experiment Video
Updated: Nov 4, 2025

Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research
Published on: October 22, 2014
Ultrasound evaluation of the radial artery in young adults - A pilot study
Zygmunt Domagała1, Joanna Grzelak2, Natalie Pospiech3
1Division of Anatomy Department of Human Morphology and Embryology, Wroclaw Medical University, Poland.
Abstract:
The radial artery is a vessel frequently used in various medical procedures which carry a risk of complications. One such method used to minimize the number of complications is a profound knowledge of the artery's diameter, which allows for appropriate selection of an instrument to use for puncture. The purpose of this study is to determine the diameter of the radial artery and its depth from the skin surface in young adults.
Material And Methods:
96 volunteers participated in the study. The average age of the volunteers was 20.43 years. All participants underwent a B-mode ultrasonography to measure the distal radial artery's diameter. Certified anthropometric instruments were used to determine the relation between the artery diameter and the selected basic anthropometric parameters.
Results:
The mean right arterial diameter for the entire examined population at the level of the styloid process was mean 1.42 (SD 0.26) mm and its distance to the skin was mean 4.00 (SD1.20) mm. Statistical analysis revealed the presence of moderate positive relationship between the diameter of the radial artery and body weight and between the diameter of the radial artery and BMI. A weak correlation between the artery diameter and the width of the wrist was also present.
Conclusion:
In the present work, we aimed to determine the dimensions of the distal section of the radial artery in young people free from symptoms of cardiovascular diseases. The obtained initial study results advise selecting instruments for vascular puncture individually, with special attention paid to slender people with slim wrists.
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)

